Bently Nevada|3500/61 136711-02|Temperature Monitor Module
Bently Nevada 3500/61 136711-02 Temperature Monitor Module with Recorder Outputs
Description
The Bently Nevada 3500/61 136711-02 is a temperature monitoring module designed for machinery condition monitoring, supporting both RTD and thermocouple inputs with integrated recorder outputs.
Features
- Six channels for RTD / TC inputs (mixed or single type)
- Programmable alarm setpoints and delays
- Recorder outputs (4–20 mA) per channel
- TMR-compatible for redundant configurations
Technical Specifications
Inputs
-
Signal Types
- RTD: 100Ω platinum, 120Ω nickel, 10Ω copper
- Thermocouples: Type E, J, K, T
-
RTD Ranges
- Platinum (0.00385 alpha): -200°C to +850°C
- Nickel: -80°C to +260°C
- Copper: -100°C to +260°C
-
TC Ranges
- Type E: -100°C to +1000°C
- Type K: -18°C to +1370°C
Performance
-
Resolution
- 1°C / °F
-
Accuracy
- ±1°C to ±3°C (varies by termination type)
-
Alarm Accuracy
- ±0.13% of setpoint
Electrical
-
RTD Current Source
- 925 µA ±15 µA
-
Recorder Output
- 4–20 mA
- 0–600 Ω load
-
Power Consumption
- 9W nominal
Isolation
- Channel-to-channel: 250Vdc
- System isolation: 500Vdc
Environmental
- Operating Temperature: -30°C to +65°C
- Storage Temperature: -40°C to +85°C
Physical
- Dimensions: 241.3 mm × 24.4 mm × 241.8 mm
- Weight: 0.91 kg
Bently Nevada|3500/61 136711-02|Temperature Monitor Module



Bently Nevada|3500/61 136711-02|Temperature Monitor Module
Bently Nevada 3500/61 136711-02 Temperature Monitor Module with Recorder Outputs
Description
The Bently Nevada 3500/61 136711-02 is a temperature monitoring module designed for machinery condition monitoring, supporting both RTD and thermocouple inputs with integrated recorder outputs.
Features
- Six channels for RTD / TC inputs (mixed or single type)
- Programmable alarm setpoints and delays
- Recorder outputs (4–20 mA) per channel
- TMR-compatible for redundant configurations
Technical Specifications
Inputs
-
Signal Types
- RTD: 100Ω platinum, 120Ω nickel, 10Ω copper
- Thermocouples: Type E, J, K, T
-
RTD Ranges
- Platinum (0.00385 alpha): -200°C to +850°C
- Nickel: -80°C to +260°C
- Copper: -100°C to +260°C
-
TC Ranges
- Type E: -100°C to +1000°C
- Type K: -18°C to +1370°C
Performance
-
Resolution
- 1°C / °F
-
Accuracy
- ±1°C to ±3°C (varies by termination type)
-
Alarm Accuracy
- ±0.13% of setpoint
Electrical
-
RTD Current Source
- 925 µA ±15 µA
-
Recorder Output
- 4–20 mA
- 0–600 Ω load
-
Power Consumption
- 9W nominal
Isolation
- Channel-to-channel: 250Vdc
- System isolation: 500Vdc
Environmental
- Operating Temperature: -30°C to +65°C
- Storage Temperature: -40°C to +85°C
Physical
- Dimensions: 241.3 mm × 24.4 mm × 241.8 mm
- Weight: 0.91 kg