Yokogawa F3PU30-0S Power Supply Module

SKU: F3PU30-0S
  • Manufacturer: Yokogawa

  • Product No.: F3PU30-0S

  • Condition:In stock

  • Product Type:

  • Product Origin: Japan

  • Payment:T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

The Yokogawa F3PU30-0S , also cataloged as the F3PU30 Power Supply Module, operates as a dedicated hardware component for primary system power conversion and backplane power distribution within Yokogawa FA-M3 Range-free Multi-controller platforms.

Hardware Specifications

Parameter Specification
Model F3PU30-0S
Brand Yokogawa
Origin Japan
Weight 3.0 kg
Dimensions Standard FA-M3 Power Supply Footprint
Operating Temp 0 deg C to 55 deg C
Power Consumption 100 VA
Nominal Supply Voltage 100-240 VAC (single-phase), 50/60 Hz / 24 VDC
Voltage Fluctuation Range 85-264 VAC, 50/60 Hz +/-3 Hz
Rated Output Voltage 5 VDC
Inrush Current 20 A max (120 VAC, Ta=25 deg C) / 45 A max (240 VAC, Ta=25 deg C)
Allowable Power Failure 20 ms momentary hold-up time

DCS Signal Conditioning & Field Loop Protocol Features

The F3PU30-0S power supply module incorporates internal isolation and voltage regulation logic to deliver continuous 5 VDC power to the FA-M3 backplane bus. Engineered with built-in noise filtering and surge suppression networks, the power stage prevents line transients and electromagnetic interference on the AC power mains from corrupting system memory and digital signal processing. The module maintains a 20 ms ride-through hold-up time during voltage sags, preserving CPU logic execution and system backplane communications across downstream 4-20 mA HART loop protocol instruments and digital I/O nodes.

Frequently Asked Questions

Q: What is the allowable input voltage fluctuation range for the F3PU30-0S?

A: The module operates reliably within an extended input voltage range of 85 to 264 VAC at 50/60 Hz (+/-3 Hz).

Q: How long can the F3PU30-0S sustain output power during a momentary main power supply interruption?

A: The unit features an allowable momentary power failure time of up to 20 ms before the 5 VDC output rail drops out.

Field Installation Guidelines

  1. Ensure the main AC power distribution feeder is isolated and locked out before wiring line terminals to the F3PU30-0S input block.
  2. Fasten the module securely into the designated left-most slot of the FA-M3 base unit to establish chassis ground contact.
  3. Connect dedicated protective earth (PE) grounding conductors directly to the unit's earth terminal using low-impedance cabling.
  4. Allow sufficient clearance around the power supply heat sink channels to ensure natural convection cooling during continuous high-load operation.
Order and Warranty Information

Terms of Purchase and Returns

Detailed guidelines on minimum order quantity, delivery times, payment options, warranty, and return policies.

We gladly accept bulk orders, with a minimum order quantity of just one unit.

Upon request, we can provide all necessary documents, including Certificates of Origin/Conformance and other required export paperwork.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% payable before shipment. For RMB transfers, please contact us if you have an agent in China.

All new and original items come with a standard one-year warranty. For extended warranty options, feel free to contact us for pricing details.

We prioritize your satisfaction. If you need to return an item, it must be done within 30 days of purchase. The product must be unused, unopened, and in its original packaging, including all accessories. Refunds will be processed within 5-7 business days of receiving the return. Please note, shipping and handling charges are non-refundable.

Product comparison