YOKOGAWA ADV551-P50 CENTUM VP Output Module
Configured for pulse-width time-proportional actuation and discrete load switching in CENTUM VP control systems, the Yokogawa ADV551-P50 (ADV551 Digital Output Module) provides direct physical/electrical execution.
Suffix Breakdown & Model Matrix
| Base Catalog Number | Suffix Code | Option Code | Functional Description / Configuration |
|---|---|---|---|
| ADV551 | -P50 | /D5S00 | 32-Channel Digital Output Module (With Pulse Width Function, Standard Bezel, Terminal Block ATD5S-00) |
| ADV551 | -P60 | /D5S00 | 32-Channel Digital Output Module (With Pulse Width Function, Status Display, Terminal Block ATD5S-00) |
| ADV551 | -P50 | /D5A00 | 32-Channel Digital Output Module (With Pulse Width Function, KS Cable Interface Adapter) |
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | ADV551-P50 |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 0.30 kg |
| Dimensions | Standard CENTUM FIO I/O Module Form Factor |
| Operating Temp | 0 to 50 deg C |
| Power Consumption | 350 mA max at 5 VDC system bus draw |
| Channel Count | 32 channels |
| Rated Output Voltage | 24 VDC |
| Output Format | Current sink type |
| Status Display | 5 = Without status display; with no explosion protection |
| Functional Type | 0 = Basic type |
| Interface Option | /D5S00 (Model ATD5S-00 Pressure Clamp Terminal Block) |
| Shipping Weight | 2.0 kg |
Channel-to-Channel Isolation and DCS Integration
The ADV551-P50 incorporates dedicated optocoupler channel-to-system galvanic isolation rated for 2 kV AC dielectric withstand to insulate system backplane logic from external field electrical noise. Internal digital output processing circuits manage pulse-width timing and discrete state transitions directly on the hardware plane. Output data routes seamlessly through the 4-20 mA HART loop and DCS signal interface structures, ensuring deterministic fieldbus data updates across all 32 output channels.
Frequently Asked Questions
Q: What front-panel display features are provided on the ADV551-P50 variant?
A: Per suffix code configuration '5', the ADV551-P50 model is built without channel status display LEDs on the front bezel and has no explosion protection rating.
Q: What termination hardware is supplied when option code /D5S00 is specified?
A: Option /D5S00 supplies the Model ATD5S-00 pressure clamp terminal block designed for direct field wire termination to 32 digital output channels.
Q: How are field load grounds grouped across the 32 channels on this module?
A: Output channels share galvanic isolation with dedicated common negative (-) returns segmented across independent 16-channel groups.
Field Installation Guidelines
- Isolate main power from the I/O node chassis backplane prior to inserting or removing the ADV551-P50 module.
- Slide the module board into the designated rack slot guides and press until top and bottom locking levers snap into position.
- Secure the ATD5S-00 pressure clamp terminal block onto the front connector faceplate and tighten side retaining screws.
- Route 24 VDC field load wiring strictly following current-sinking polarity guidelines, separating DC output lines from high-voltage AC conductors.
- Ground overall cable shields directly to the single-point cabinet earth bar in accordance with Yokogawa DCS installation standards.
YOKOGAWA ADV551-P50 CENTUM VP Output Module
YOKOGAWA ADV551-P50 CENTUM VP Output Module
Configured for pulse-width time-proportional actuation and discrete load switching in CENTUM VP control systems, the Yokogawa ADV551-P50 (ADV551 Digital Output Module) provides direct physical/electrical execution.
Suffix Breakdown & Model Matrix
| Base Catalog Number | Suffix Code | Option Code | Functional Description / Configuration |
|---|---|---|---|
| ADV551 | -P50 | /D5S00 | 32-Channel Digital Output Module (With Pulse Width Function, Standard Bezel, Terminal Block ATD5S-00) |
| ADV551 | -P60 | /D5S00 | 32-Channel Digital Output Module (With Pulse Width Function, Status Display, Terminal Block ATD5S-00) |
| ADV551 | -P50 | /D5A00 | 32-Channel Digital Output Module (With Pulse Width Function, KS Cable Interface Adapter) |
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | ADV551-P50 |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 0.30 kg |
| Dimensions | Standard CENTUM FIO I/O Module Form Factor |
| Operating Temp | 0 to 50 deg C |
| Power Consumption | 350 mA max at 5 VDC system bus draw |
| Channel Count | 32 channels |
| Rated Output Voltage | 24 VDC |
| Output Format | Current sink type |
| Status Display | 5 = Without status display; with no explosion protection |
| Functional Type | 0 = Basic type |
| Interface Option | /D5S00 (Model ATD5S-00 Pressure Clamp Terminal Block) |
| Shipping Weight | 2.0 kg |
Channel-to-Channel Isolation and DCS Integration
The ADV551-P50 incorporates dedicated optocoupler channel-to-system galvanic isolation rated for 2 kV AC dielectric withstand to insulate system backplane logic from external field electrical noise. Internal digital output processing circuits manage pulse-width timing and discrete state transitions directly on the hardware plane. Output data routes seamlessly through the 4-20 mA HART loop and DCS signal interface structures, ensuring deterministic fieldbus data updates across all 32 output channels.
Frequently Asked Questions
Q: What front-panel display features are provided on the ADV551-P50 variant?
A: Per suffix code configuration '5', the ADV551-P50 model is built without channel status display LEDs on the front bezel and has no explosion protection rating.
Q: What termination hardware is supplied when option code /D5S00 is specified?
A: Option /D5S00 supplies the Model ATD5S-00 pressure clamp terminal block designed for direct field wire termination to 32 digital output channels.
Q: How are field load grounds grouped across the 32 channels on this module?
A: Output channels share galvanic isolation with dedicated common negative (-) returns segmented across independent 16-channel groups.
Field Installation Guidelines
- Isolate main power from the I/O node chassis backplane prior to inserting or removing the ADV551-P50 module.
- Slide the module board into the designated rack slot guides and press until top and bottom locking levers snap into position.
- Secure the ATD5S-00 pressure clamp terminal block onto the front connector faceplate and tighten side retaining screws.
- Route 24 VDC field load wiring strictly following current-sinking polarity guidelines, separating DC output lines from high-voltage AC conductors.
- Ground overall cable shields directly to the single-point cabinet earth bar in accordance with Yokogawa DCS installation standards.