Honeywell|8U-TCNTA1|Thermocouple/RTD Input IOTA Module
HONEYWELL 8U-TCNTA1 Thermocouple/RTD Input IOTA Module
Description
The HONEYWELL 8U-TCNTA1 is a low-level analog input module of the IOTA series, specifically engineered for direct connection and precise measurement of thermocouple and RTD temperature sensors in industrial control systems.
The HONEYWELL 8U-TCNTA1 is a low-level analog input module of the IOTA series, specifically engineered for direct connection and precise measurement of thermocouple and RTD temperature sensors in industrial control systems.
Features
- Dedicated to thermocouple (TC) and resistance temperature detector (RTD) inputs
- Built-in cold junction compensation for TC types
- High noise immunity and signal conditioning
- Compatible with Honeywell TPS and Experion PKS platforms
Technical Specifications
- Input Type: Low-level analog for TC and RTD
- Supported TC Types: J, K, T, E, R, S, B, N
- Supported RTD Types: Pt100, Pt500, Ni100, Cu10 (2-, 3-, or 4-wire)
- Measurement Accuracy: ±0.15°C for RTD; ±1.0°C typical for TC
- Resolution: 16-bit A/D conversion
- Sampling Rate: Up to 4 samples per second per channel
- Cold Junction Compensation: Integrated, ±0.5°C accuracy
- Operating Temperature: –20°C to +70°C
- Isolation: 500 VDC field-to-system isolation
- Power Supply: Powered via IOPS unit
- Backplane Interface: IOHIGHWAY at 1.2 Mbit/s or 4 Mbit/s
- Channel Count: Typically 8 channels per module
Honeywell|8U-TCNTA1|Thermocouple/RTD Input IOTA Module
Current product
Current
Vendor:
Honeywell
Honeywell|8U-TCNTA1|Thermocouple/RTD Input IOTA Module
Regular price
$100.00
Sale price
$100.00
Regular price
$300.00
Options
Descriptions
HONEYWELL 8U-TCNTA1 Thermocouple/RTD Input IOTA Module
Description
The HONEYWELL 8U-TCNTA1 is a low-level analog input module of the IOTA series, specifically engineered for direct connection and precise measurement of thermocouple and RTD temperature sensors in industrial control systems.
The HONEYWELL 8U-TCNTA1 is a low-level analog input module of the IOTA series, specifically engineered for direct connection and precise measurement of thermocouple and RTD temperature sensors in industrial control systems.
Features
- Dedicated to thermocouple (TC) and resistance temperature detector (RTD) inputs
- Built-in cold junction compensation for TC types
- High noise immunity and signal conditioning
- Compatible with Honeywell TPS and Experion PKS platforms
Technical Specifications
- Input Type: Low-level analog for TC and RTD
- Supported TC Types: J, K, T, E, R, S, B, N
- Supported RTD Types: Pt100, Pt500, Ni100, Cu10 (2-, 3-, or 4-wire)
- Measurement Accuracy: ±0.15°C for RTD; ±1.0°C typical for TC
- Resolution: 16-bit A/D conversion
- Sampling Rate: Up to 4 samples per second per channel
- Cold Junction Compensation: Integrated, ±0.5°C accuracy
- Operating Temperature: –20°C to +70°C
- Isolation: 500 VDC field-to-system isolation
- Power Supply: Powered via IOPS unit
- Backplane Interface: IOHIGHWAY at 1.2 Mbit/s or 4 Mbit/s
- Channel Count: Typically 8 channels per module