GE Multilin|D25-0158-000001|Multifunction Bay Controller/RTU
GE Multilin D25-0158-000001 Multifunction Bay Controller/RTU
Description
The GE Multilin D25-0158-000001 is a modular, compact RTU for substation automation, integrating control, metering, fault recording, and communication functions.
Features
- Synchronism check with bypass for dead/live bus-line conditions
- Supports dual-busbar schemes and up to 255 concurrent auto-restorations
- IEC 61850-compliant with GOOSE, LogicLinx® PLC logic, and protocol conversion for 120+ SCADA protocols
- Local HMI with touch screen, digital fault recording, and harmonic analysis up to 21st order
- Built-in transformer monitoring models and configurable load shedding
Technical Specifications
- AC analog inputs: up to 15 (1A/5A CTs; 63.5V–220V PTs); accuracy ±0.3% (Fluxbuster™ mode)
- DC analog inputs: 16 channels (±5V or ±1/5/10/20mA); accuracy ±0.05% full scale
- Digital inputs: up to 96 (12–250Vdc), 1 ms resolution, programmable debounce
- Digital outputs: up to 32 relays (4A continuous, 10A for 5 seconds)
- Sampling rate: 64 samples per power cycle
- Power supply: 20–350Vdc or 85–265Vac, max power 65W
- Operating temperature: –20°C to +70°C (without display)
- Communication: Ethernet (10/100TX/FX), IRIG-B, SNTP, RS-232/485
- Measurement accuracy: RMS ±0.5%, phase angle ±0.5°, frequency ±0.01Hz
- Fault recording: up to 16 MB local storage, COMTRADE format, 240-cycle capture
GE Multilin|D25-0158-000001|Multifunction Bay Controller/RTU
GE Multilin|D25-0158-000001|Multifunction Bay Controller/RTU
GE Multilin D25-0158-000001 Multifunction Bay Controller/RTU
Description
The GE Multilin D25-0158-000001 is a modular, compact RTU for substation automation, integrating control, metering, fault recording, and communication functions.
Features
- Synchronism check with bypass for dead/live bus-line conditions
- Supports dual-busbar schemes and up to 255 concurrent auto-restorations
- IEC 61850-compliant with GOOSE, LogicLinx® PLC logic, and protocol conversion for 120+ SCADA protocols
- Local HMI with touch screen, digital fault recording, and harmonic analysis up to 21st order
- Built-in transformer monitoring models and configurable load shedding
Technical Specifications
- AC analog inputs: up to 15 (1A/5A CTs; 63.5V–220V PTs); accuracy ±0.3% (Fluxbuster™ mode)
- DC analog inputs: 16 channels (±5V or ±1/5/10/20mA); accuracy ±0.05% full scale
- Digital inputs: up to 96 (12–250Vdc), 1 ms resolution, programmable debounce
- Digital outputs: up to 32 relays (4A continuous, 10A for 5 seconds)
- Sampling rate: 64 samples per power cycle
- Power supply: 20–350Vdc or 85–265Vac, max power 65W
- Operating temperature: –20°C to +70°C (without display)
- Communication: Ethernet (10/100TX/FX), IRIG-B, SNTP, RS-232/485
- Measurement accuracy: RMS ±0.5%, phase angle ±0.5°, frequency ±0.01Hz
- Fault recording: up to 16 MB local storage, COMTRADE format, 240-cycle capture