GE Multilin D25-0157-000003 Multifunction Bay Controller/RTU
GE Multilin D25-0157-000003 Multifunction Bay Controller/RTU
Description
The GE Multilin D25-0157-000003 is a modular, compact remote terminal unit (RTU) designed for substation automation, offering advanced control, metering, and communication capabilities.
Features
Supports IEC 61850 with GOOSE messaging, protocol conversion for over 120 SCADA protocols, synchronism check with bypass, auto restoration for up to 255 feeders, and programmable logic via LogicLinx®. Includes digital fault recording, power quality monitoring, and transformer diagnostics.
Technical Specifications
- AC Analog Inputs: Up to 15 inputs; supports 1A/5A CTs and PTs (63.5 V to 220 V); measurement accuracy ±0.3% (Fluxbuster™ high-current option).
- DC Analog Inputs: 16 channels; ±5 V or ±1/5/10/20 mA ranges; accuracy ±0.05% (voltage), ±0.10% (current).
- Digital I/O: Up to 96 optically isolated inputs (12–250 Vdc); up to 32 digital outputs (4 A continuous, 10 A for 5 sec).
- Sampling & Recording: 64 samples/cycle; records COMTRADE oscillography files with up to 240 cycles and 250 digital status points; local storage up to 16 MB.
- Harmonics & Power Quality: Measures up to 21st harmonic; THD calculation; RMS profiling for up to 6 AC circuits.
- Communications: Dual Ethernet (10/100 Mbps) or serial ports; supports IEC 61850, Modbus, DNP3, and more; KEMA® certified.
- Power Supply: Options include 20–60 Vdc, 60–150 Vdc/120 Vac, or 150–350 Vdc/220 Vac.
- Operating Temperature: –20°C to +70°C (without display); 0°C to +50°C (with graphical HMI).
- Physical: 19" W × 8.75" H × 9" D; max weight 31 lbs (14.1 kg).
GE Multilin D25-0157-000003 Multifunction Bay Controller/RTU
GE Multilin D25-0157-000003 Multifunction Bay Controller/RTU
GE Multilin D25-0157-000003 Multifunction Bay Controller/RTU
Description
The GE Multilin D25-0157-000003 is a modular, compact remote terminal unit (RTU) designed for substation automation, offering advanced control, metering, and communication capabilities.
Features
Supports IEC 61850 with GOOSE messaging, protocol conversion for over 120 SCADA protocols, synchronism check with bypass, auto restoration for up to 255 feeders, and programmable logic via LogicLinx®. Includes digital fault recording, power quality monitoring, and transformer diagnostics.
Technical Specifications
- AC Analog Inputs: Up to 15 inputs; supports 1A/5A CTs and PTs (63.5 V to 220 V); measurement accuracy ±0.3% (Fluxbuster™ high-current option).
- DC Analog Inputs: 16 channels; ±5 V or ±1/5/10/20 mA ranges; accuracy ±0.05% (voltage), ±0.10% (current).
- Digital I/O: Up to 96 optically isolated inputs (12–250 Vdc); up to 32 digital outputs (4 A continuous, 10 A for 5 sec).
- Sampling & Recording: 64 samples/cycle; records COMTRADE oscillography files with up to 240 cycles and 250 digital status points; local storage up to 16 MB.
- Harmonics & Power Quality: Measures up to 21st harmonic; THD calculation; RMS profiling for up to 6 AC circuits.
- Communications: Dual Ethernet (10/100 Mbps) or serial ports; supports IEC 61850, Modbus, DNP3, and more; KEMA® certified.
- Power Supply: Options include 20–60 Vdc, 60–150 Vdc/120 Vac, or 150–350 Vdc/220 Vac.
- Operating Temperature: –20°C to +70°C (without display); 0°C to +50°C (with graphical HMI).
- Physical: 19" W × 8.75" H × 9" D; max weight 31 lbs (14.1 kg).