The IS200EPCTG1A is an Exciter PT/CT Board (EPCT) designed for the GE EX2100 excitation control system. It receives generator potential transformer (PT) voltage and current transformer (CT) current feedback, then conditions, scales, and isolates these signals for the excitation control system. The board supports feedback inputs from two generators and provides three terminal blocks for field wiring.
Product Specifications
Parameter
Specification
Model
IS200EPCTG1A
Brand
General Electric (GE)
Series
EX2100
Functional Acronym
EPCT
Board Description
Exciter PT/CT Board
Board Type
Input/Output Terminal Board
Primary Function
Generator PT/CT feedback reception and signal conditioning
Generator Feedback Sources
Two generators
PT Input Configuration
Three-phase generator voltage
CT Input Current Levels
1 A or 5 A
Analog Input Signal Range
0-10 V or 4-20 mA
PT/CT Input Burden
Less than 1 VA
Terminal Blocks
3
Maximum Wire Gauge
#10 AWG
Maximum Cable Length
1000 ft
High-Frequency Noise Suppression
Supported
Redundant System Configuration
Up to 3 EPCT boards, if required
PT and CT Feedback Processing
The IS200EPCTG1A receives voltage and current feedback from generator PTs and CTs. Its PT inputs accommodate three-phase voltage feedback, while its CT inputs accept nominal current levels of 1 A or 5 A from two generators.
The board conditions these incoming signals by scaling and isolating them before interfacing with the excitation control system. This allows generator electrical measurements to be presented in a suitable form for downstream control and monitoring functions.
Analog Signal Conditioning and Noise Suppression
The EPCT supports analog signal ranges of 0-10 V and 4-20 mA. These ranges are relevant when identifying the signal interface and checking the wiring requirements of the connected measurement circuits.
High-frequency noise suppression is provided near the signal entry point. This helps limit high-frequency interference entering through field wiring before the signals are processed by the board.
Wiring and Terminal Connections
The board provides three terminal blocks for PT and CT signal connections. The specified maximum conductor size is #10 AWG, and the maximum cable length is 1000 ft.
PT and CT wiring should be checked against the actual generator measurement circuit configuration. Correct identification of current transformer polarity, phase association, and voltage input connections is necessary when commissioning or replacing the board.
Measurement and Redundant Configuration
For a three-wire open-delta voltage measurement, the supplied product information specifies an output measurement of 1.533 VRMS for a 115 VRMS input. This value is associated with the stated open-delta measurement condition and should not be treated as a universal voltage conversion ratio for other PT configurations.
Although EPCT boards are generally not required in redundant system configurations, the supplied technical information indicates that up to three EPCT boards can be configured when the system design requires them.
Frequently Asked Questions
Q: What CT current input levels does the IS200EPCTG1A accept?
A: The board accepts generator CT input levels of 1 A or 5 A. The received signals are also interfaced to the EMIO board.
Q: Does the IS200EPCTG1A provide high-frequency noise suppression?
A: Yes. High-frequency noise suppression is applied near the signal entry point to help reduce interference entering through the field connections.
Q: What measurement does the board provide for a three-wire open-delta configuration?
A: The supplied technical data specifies 1.533 VRMS for a 115 VRMS input under the stated three-wire open-delta measurement condition.
Q: How many EPCT boards can be used in a redundant system?
A: Up to three EPCT boards can be configured if required. However, EPCT boards are generally not necessary in redundant system configurations.
GE IS200EPCTG1A EX2100 PT/CT Terminal Board
1 / of3
Order and Warranty Information
Terms of Purchase and Returns
Detailed guidelines on minimum order quantity, delivery times, payment options, warranty, and return policies.
We gladly accept bulk orders, with a minimum order quantity of just one unit.
Upon request, we can provide all necessary documents, including Certificates of Origin/Conformance and other required export paperwork.
We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% payable before shipment. For RMB transfers, please contact us if you have an agent in China.
All new and original items come with a standard one-year warranty. For extended warranty options, feel free to contact us for pricing details.
We prioritize your satisfaction. If you need to return an item, it must be done within 30 days of purchase. The product must be unused, unopened, and in its original packaging, including all accessories. Refunds will be processed within 5-7 business days of receiving the return. Please note, shipping and handling charges are non-refundable.
The IS200EPCTG1A is an Exciter PT/CT Board (EPCT) designed for the GE EX2100 excitation control system. It receives generator potential transformer (PT) voltage and current transformer (CT) current feedback, then conditions, scales, and isolates these signals for the excitation control system. The board supports feedback inputs from two generators and provides three terminal blocks for field wiring.
Product Specifications
Parameter
Specification
Model
IS200EPCTG1A
Brand
General Electric (GE)
Series
EX2100
Functional Acronym
EPCT
Board Description
Exciter PT/CT Board
Board Type
Input/Output Terminal Board
Primary Function
Generator PT/CT feedback reception and signal conditioning
Generator Feedback Sources
Two generators
PT Input Configuration
Three-phase generator voltage
CT Input Current Levels
1 A or 5 A
Analog Input Signal Range
0-10 V or 4-20 mA
PT/CT Input Burden
Less than 1 VA
Terminal Blocks
3
Maximum Wire Gauge
#10 AWG
Maximum Cable Length
1000 ft
High-Frequency Noise Suppression
Supported
Redundant System Configuration
Up to 3 EPCT boards, if required
PT and CT Feedback Processing
The IS200EPCTG1A receives voltage and current feedback from generator PTs and CTs. Its PT inputs accommodate three-phase voltage feedback, while its CT inputs accept nominal current levels of 1 A or 5 A from two generators.
The board conditions these incoming signals by scaling and isolating them before interfacing with the excitation control system. This allows generator electrical measurements to be presented in a suitable form for downstream control and monitoring functions.
Analog Signal Conditioning and Noise Suppression
The EPCT supports analog signal ranges of 0-10 V and 4-20 mA. These ranges are relevant when identifying the signal interface and checking the wiring requirements of the connected measurement circuits.
High-frequency noise suppression is provided near the signal entry point. This helps limit high-frequency interference entering through field wiring before the signals are processed by the board.
Wiring and Terminal Connections
The board provides three terminal blocks for PT and CT signal connections. The specified maximum conductor size is #10 AWG, and the maximum cable length is 1000 ft.
PT and CT wiring should be checked against the actual generator measurement circuit configuration. Correct identification of current transformer polarity, phase association, and voltage input connections is necessary when commissioning or replacing the board.
Measurement and Redundant Configuration
For a three-wire open-delta voltage measurement, the supplied product information specifies an output measurement of 1.533 VRMS for a 115 VRMS input. This value is associated with the stated open-delta measurement condition and should not be treated as a universal voltage conversion ratio for other PT configurations.
Although EPCT boards are generally not required in redundant system configurations, the supplied technical information indicates that up to three EPCT boards can be configured when the system design requires them.
Frequently Asked Questions
Q: What CT current input levels does the IS200EPCTG1A accept?
A: The board accepts generator CT input levels of 1 A or 5 A. The received signals are also interfaced to the EMIO board.
Q: Does the IS200EPCTG1A provide high-frequency noise suppression?
A: Yes. High-frequency noise suppression is applied near the signal entry point to help reduce interference entering through the field connections.
Q: What measurement does the board provide for a three-wire open-delta configuration?
A: The supplied technical data specifies 1.533 VRMS for a 115 VRMS input under the stated three-wire open-delta measurement condition.
Q: How many EPCT boards can be used in a redundant system?
A: Up to three EPCT boards can be configured if required. However, EPCT boards are generally not necessary in redundant system configurations.
Express Shipping
Fast and efficient delivery for urgent requirements.
Extensive Inventory
A large selection of stock for prompt availability.
Quality Assurance
Authentic, premium-grade PLC and DCS components.
Global Service
Serving clients globally with dependable customer support.
Variant picker
Choosing a selection results in a full page refresh.