Foxboro|P0918EU| Communication Module
FOXBORO P0918EU I/A Series Redundant Communication Module
Description
The FOXBORO P0918EU is a redundant communication module in the Foxboro I/A Series, providing fault-tolerant serial data links for critical industrial control networks.
The FOXBORO P0918EU is a redundant communication module in the Foxboro I/A Series, providing fault-tolerant serial data links for critical industrial control networks.
Features
- Dual redundant RS-485/RS-422 channels
- Automatic failover with heartbeat monitoring
- Supports Modbus RTU and FoxCom protocols
- Isolated ports with ESD and surge protection
Technical Specifications
- Communication channels: 2 redundant serial ports
- Interface type: RS-485 / RS-422 (software-selectable)
- Baud rate: 300 to 115,200 bps
- Isolation voltage: 2500 Vrms between port and backplane
- Redundancy switchover time: <100 ms
- Operating temperature: -20°C to +70°C
- Power consumption: approximately 4.0 W
- Module dimensions: 240 mm (H) × 30 mm (W) × 220 mm (D)
- Weight: 0.65 kg
- Backplane compatibility: standard FBM baseplate (e.g., P0926JM)
- Compliance: IEC 61131-2, CE, RoHS
- MTBF: greater than 150,000 hours
Foxboro|P0918EU| Communication Module
Current product
Current
Vendor:
Foxboro
Foxboro|P0918EU| Communication Module
Regular price
$95.00
Sale price
$95.00
Regular price
$300.00
Options
Descriptions
FOXBORO P0918EU I/A Series Redundant Communication Module
Description
The FOXBORO P0918EU is a redundant communication module in the Foxboro I/A Series, providing fault-tolerant serial data links for critical industrial control networks.
The FOXBORO P0918EU is a redundant communication module in the Foxboro I/A Series, providing fault-tolerant serial data links for critical industrial control networks.
Features
- Dual redundant RS-485/RS-422 channels
- Automatic failover with heartbeat monitoring
- Supports Modbus RTU and FoxCom protocols
- Isolated ports with ESD and surge protection
Technical Specifications
- Communication channels: 2 redundant serial ports
- Interface type: RS-485 / RS-422 (software-selectable)
- Baud rate: 300 to 115,200 bps
- Isolation voltage: 2500 Vrms between port and backplane
- Redundancy switchover time: <100 ms
- Operating temperature: -20°C to +70°C
- Power consumption: approximately 4.0 W
- Module dimensions: 240 mm (H) × 30 mm (W) × 220 mm (D)
- Weight: 0.65 kg
- Backplane compatibility: standard FBM baseplate (e.g., P0926JM)
- Compliance: IEC 61131-2, CE, RoHS
- MTBF: greater than 150,000 hours