Bently Nevada|83729-01|Temperature Monitor Module
BENTLY NEVADA 83729-01 Temperature Monitor Module
Description
BENTLY NEVADA 83729-01 is a temperature monitoring module designed to interface with RTD or thermocouple sensors for precise thermal protection in the 3500 machinery monitoring system.
BENTLY NEVADA 83729-01 is a temperature monitoring module designed to interface with RTD or thermocouple sensors for precise thermal protection in the 3500 machinery monitoring system.
Features
- Supports RTD and thermocouple inputs
- Provides high-accuracy temperature measurement
- Configurable alarm and trip thresholds
- Fully compatible with 3500 rack architecture
Technical Specifications
- Input Channels: 8 differential analog inputs
- Sensor Types: Pt100, Pt1000 RTDs; Type J, K, T, E thermocouples
- Measurement Range: -200°C to +850°C (sensor-dependent)
- Accuracy: ±0.5°C typical for RTD inputs
- Resolution: 0.1°C
- A/D Conversion: 16-bit per channel
- Operating Voltage: 24 VDC nominal (±10%)
- Power Consumption: Approximately 4.0 W
- Operating Temperature: 0°C to +65°C
- Storage Temperature: -40°C to +85°C
- Relative Humidity: 5% to 95%, non-condensing
- Isolation: 500 VAC between field wiring and system ground
- Module Dimensions: Standard 3500 chassis slot (approx. 24 mm wide × 180 mm high × 240 mm deep)
- Mounting: Hot-swappable in 3500 rack
Bently Nevada|83729-01|Temperature Monitor Module
Current product
Current
Vendor:
BENTLY NEVADA
Bently Nevada|83729-01|Temperature Monitor Module
Regular price
$190.00
Sale price
$190.00
Regular price
$430.00
Options
Descriptions
BENTLY NEVADA 83729-01 Temperature Monitor Module
Description
BENTLY NEVADA 83729-01 is a temperature monitoring module designed to interface with RTD or thermocouple sensors for precise thermal protection in the 3500 machinery monitoring system.
BENTLY NEVADA 83729-01 is a temperature monitoring module designed to interface with RTD or thermocouple sensors for precise thermal protection in the 3500 machinery monitoring system.
Features
- Supports RTD and thermocouple inputs
- Provides high-accuracy temperature measurement
- Configurable alarm and trip thresholds
- Fully compatible with 3500 rack architecture
Technical Specifications
- Input Channels: 8 differential analog inputs
- Sensor Types: Pt100, Pt1000 RTDs; Type J, K, T, E thermocouples
- Measurement Range: -200°C to +850°C (sensor-dependent)
- Accuracy: ±0.5°C typical for RTD inputs
- Resolution: 0.1°C
- A/D Conversion: 16-bit per channel
- Operating Voltage: 24 VDC nominal (±10%)
- Power Consumption: Approximately 4.0 W
- Operating Temperature: 0°C to +65°C
- Storage Temperature: -40°C to +85°C
- Relative Humidity: 5% to 95%, non-condensing
- Isolation: 500 VAC between field wiring and system ground
- Module Dimensions: Standard 3500 chassis slot (approx. 24 mm wide × 180 mm high × 240 mm deep)
- Mounting: Hot-swappable in 3500 rack