Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 6189-RDT12C |
| Brand | Allen-Bradley / Rockwell Automation |
| Origin | USA |
| Weight | 2.27 kg (5.00 lbs) |
| Dimensions | 12.1-inch VersaView 1250 panel cutout profile |
| Operating Temp | 0 deg C to +50 deg C |
| Power Consumption | Powered via connected VersaView logic module |
| Series | VersaView 1250 |
| Touch Technology | Analog Resistive Touch Screen |
| Display Type | Color TFT Display Module |
| Category | Operator Interface / HMI Touch Module |
Backplane Communication and Network Determinism
The 6189-RDT12C touch screen display module interfaces directly with host processing units over high-speed internal display buses. When integrated into EtherNet/IP deterministic networks via an attached VersaView logic module, touch coordinate data and status signals are passed to ControlLogix or CompactLogix PLCs with minimal input latency. High backplane bus communication velocity guarantees rapid screen redrawn cycles, continuous operator command acquisition, and consistent firmware flash compatibility across legacy control cabinet installations.
Frequently Asked Questions
Q: How is the 6189-RDT12C display module powered during standard operation?
A: The module receives its operational power and backlighting drive voltage directly through the ribbon connector interface attached to the mating rear VersaView logic engine.
Q: What sealing rating is achieved when the 6189-RDT12C is correctly mounted in a cabinet cut-out?
A: When panel-mounted using all peripheral mounting clips and the original sealing gasket, the front bezel meets NEMA Type 12, 4X (indoor use only), and IP65 dust/water washdown ingress standards.
Field Installation Guidelines
- Verify panel cutout dimensions match the standard VersaView 1250 enclosure specifications prior to positioning the unit.
- Inspect the perimeter sealing gasket on the rear bezel for tears, debris, or compression set before insertion.
- Slide the 6189-RDT12C module into the panel cutout from the front, supporting its weight until initial clips engage.
- Install all mounting levers or clamps around the rear rim, tightening screws in an alternating star pattern to achieve uniform gasket compression.
- Securely latch the interface ribbon cable from the logic module to the display backplane connector before restoring power.
Allen-Bradley 6189-RDT12C VersaView 1250 Touch Screen Module
Allen-Bradley 6189-RDT12C VersaView 1250 Touch Screen Module
The Allen-Bradley 6189-RDT12C serves as the primary 6189-RDT12C Touch Screen Module utilized to execute localized touch-input execution across VersaView 1250 platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 6189-RDT12C |
| Brand | Allen-Bradley / Rockwell Automation |
| Origin | USA |
| Weight | 2.27 kg (5.00 lbs) |
| Dimensions | 12.1-inch VersaView 1250 panel cutout profile |
| Operating Temp | 0 deg C to +50 deg C |
| Power Consumption | Powered via connected VersaView logic module |
| Series | VersaView 1250 |
| Touch Technology | Analog Resistive Touch Screen |
| Display Type | Color TFT Display Module |
| Category | Operator Interface / HMI Touch Module |
Backplane Communication and Network Determinism
The 6189-RDT12C touch screen display module interfaces directly with host processing units over high-speed internal display buses. When integrated into EtherNet/IP deterministic networks via an attached VersaView logic module, touch coordinate data and status signals are passed to ControlLogix or CompactLogix PLCs with minimal input latency. High backplane bus communication velocity guarantees rapid screen redrawn cycles, continuous operator command acquisition, and consistent firmware flash compatibility across legacy control cabinet installations.
Frequently Asked Questions
Q: How is the 6189-RDT12C display module powered during standard operation?
A: The module receives its operational power and backlighting drive voltage directly through the ribbon connector interface attached to the mating rear VersaView logic engine.
Q: What sealing rating is achieved when the 6189-RDT12C is correctly mounted in a cabinet cut-out?
A: When panel-mounted using all peripheral mounting clips and the original sealing gasket, the front bezel meets NEMA Type 12, 4X (indoor use only), and IP65 dust/water washdown ingress standards.
Field Installation Guidelines
- Verify panel cutout dimensions match the standard VersaView 1250 enclosure specifications prior to positioning the unit.
- Inspect the perimeter sealing gasket on the rear bezel for tears, debris, or compression set before insertion.
- Slide the 6189-RDT12C module into the panel cutout from the front, supporting its weight until initial clips engage.
- Install all mounting levers or clamps around the rear rim, tightening screws in an alternating star pattern to achieve uniform gasket compression.
- Securely latch the interface ribbon cable from the logic module to the display backplane connector before restoring power.