Allen-Bradley 2711P-T7C6A6 PanelView Plus 700
Configured for real-time human-machine interface execution and controller telemetry in Allen-Bradley automation networks, the Allen-Bradley 2711P-T7C6A6 (2711P-T7C6A6 PanelView Plus 700) provides direct physical/electrical execution for process visualization and operator input command routing.
Suffix Breakdown & Model Matrix
The catalog number structure defines specific display, power, and communication hardware configurations:
- Base Series (2711P-): Identifies the PanelView Plus modular operator terminal hardware platform.
- Display Size (-T7): Designates the 6.5-inch color display graphics panel featuring resistive analog touchscreen input.
- Display Type (-C): Denotes full-color active-matrix TFT display technology.
- Communication Module (-6): Specifies integrated Data Highway Plus (DH+) and DH-485 legacy communication ports.
- Power Supply (-A): Indicates line-voltage AC operating power supply accepting 85-264 VAC input.
- Memory/Logic Module (-6): Represents the 128 MB onboard system memory architecture configuration (Series A through G).
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 2711P-T7C6A6 |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | 32.00 lbs (14.51 kg) |
| Dimensions | 14 in x 11 in x 8 in (35.5 cm x 27.9 cm x 20.3 cm) |
| Operating Temp | 0 deg C to +55 deg C |
| Power Consumption | 85-264 VAC input power |
| Display | 6.5 in. Color Active-Matrix TFT |
| Input Method | Analog Resistive Touchscreen |
| System Memory | 128 MB Flash / RAM |
| Communication Ports | DH+, DH-485, RS-232, and USB |
| Replacement Backlight | 2711P-RL7C |
| Communication Cables | 1770-CD and 1761-CBL-AS03 |
| Compatible Series | Series A, B, C, D, E, F, G |
Deterministic Network & Backplane Integration
Configured for legacy PLC-5 and SLC 500 controller connectivity, the module utilizes deterministic network protocols over DH+ and DH-485 physical channels to execute high-speed data file transfer. The logic module architecture maintains high-density I/O register mapping while providing backplane bus communication velocity across system networks. Onboard firmware flash compatibility ensures direct tag database synchronization without requiring extensive ladder logic overhead on the host programmable logic controller.
Frequently Asked Questions
Q: What communication cables are required to connect the 2711P-T7C6A6 terminal to a DH+ or DH-485 network?
A: Interfacing with DH+ networks utilizes the 1770-CD blue hose cable assembly, whereas DH-485 serial communication utilizes the 1761-CBL-AS03 cable interface connected to the designated port.
Q: Is the CCFL display backlight field-replaceable on this terminal?
A: Yes, the display backlight can be replaced in the field using the authorized Allen-Bradley replacement part number 2711P-RL7C when display brightness degrades.
Field Installation Guidelines
Prepare a clean rectangular panel cutout in the enclosure door according to standard PanelView 700 dimensions. Verify that the perimeter sealing gasket is properly seated in the bezel groove to maintain NEMA 4X / IP65 ingress protection before inserting the terminal into the cutout. Tighten all perimeter mounting lever clamps evenly around the chassis to specified torque values to prevent bezel distortion. Ensure the AC power feed (85-264 VAC) is wired through a dedicated circuit breaker with a protective earth wire attached directly to the ground stud on the terminal housing.
Allen-Bradley 2711P-T7C6A6 PanelView Plus 700
Allen-Bradley 2711P-T7C6A6 PanelView Plus 700
Configured for real-time human-machine interface execution and controller telemetry in Allen-Bradley automation networks, the Allen-Bradley 2711P-T7C6A6 (2711P-T7C6A6 PanelView Plus 700) provides direct physical/electrical execution for process visualization and operator input command routing.
Suffix Breakdown & Model Matrix
The catalog number structure defines specific display, power, and communication hardware configurations:
- Base Series (2711P-): Identifies the PanelView Plus modular operator terminal hardware platform.
- Display Size (-T7): Designates the 6.5-inch color display graphics panel featuring resistive analog touchscreen input.
- Display Type (-C): Denotes full-color active-matrix TFT display technology.
- Communication Module (-6): Specifies integrated Data Highway Plus (DH+) and DH-485 legacy communication ports.
- Power Supply (-A): Indicates line-voltage AC operating power supply accepting 85-264 VAC input.
- Memory/Logic Module (-6): Represents the 128 MB onboard system memory architecture configuration (Series A through G).
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 2711P-T7C6A6 |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | 32.00 lbs (14.51 kg) |
| Dimensions | 14 in x 11 in x 8 in (35.5 cm x 27.9 cm x 20.3 cm) |
| Operating Temp | 0 deg C to +55 deg C |
| Power Consumption | 85-264 VAC input power |
| Display | 6.5 in. Color Active-Matrix TFT |
| Input Method | Analog Resistive Touchscreen |
| System Memory | 128 MB Flash / RAM |
| Communication Ports | DH+, DH-485, RS-232, and USB |
| Replacement Backlight | 2711P-RL7C |
| Communication Cables | 1770-CD and 1761-CBL-AS03 |
| Compatible Series | Series A, B, C, D, E, F, G |
Deterministic Network & Backplane Integration
Configured for legacy PLC-5 and SLC 500 controller connectivity, the module utilizes deterministic network protocols over DH+ and DH-485 physical channels to execute high-speed data file transfer. The logic module architecture maintains high-density I/O register mapping while providing backplane bus communication velocity across system networks. Onboard firmware flash compatibility ensures direct tag database synchronization without requiring extensive ladder logic overhead on the host programmable logic controller.
Frequently Asked Questions
Q: What communication cables are required to connect the 2711P-T7C6A6 terminal to a DH+ or DH-485 network?
A: Interfacing with DH+ networks utilizes the 1770-CD blue hose cable assembly, whereas DH-485 serial communication utilizes the 1761-CBL-AS03 cable interface connected to the designated port.
Q: Is the CCFL display backlight field-replaceable on this terminal?
A: Yes, the display backlight can be replaced in the field using the authorized Allen-Bradley replacement part number 2711P-RL7C when display brightness degrades.
Field Installation Guidelines
Prepare a clean rectangular panel cutout in the enclosure door according to standard PanelView 700 dimensions. Verify that the perimeter sealing gasket is properly seated in the bezel groove to maintain NEMA 4X / IP65 ingress protection before inserting the terminal into the cutout. Tighten all perimeter mounting lever clamps evenly around the chassis to specified torque values to prevent bezel distortion. Ensure the AC power feed (85-264 VAC) is wired through a dedicated circuit breaker with a protective earth wire attached directly to the ground stud on the terminal housing.