Allen-Bradley 2711-TC4 PanelView 1200 Operator Terminal
TheAllen-Bradley 2711-TC4 , also cataloged as the 2711-TC4 PanelView 1200 Operator Terminal, operates as a dedicated hardware component for industrial process visualization and control input within Allen-Bradley PLC networks. It executes real-time graphic display rendering and touchscreen operator commands via a 10.1-inch color display utilizing Remote I/O communication protocols powered by 90-130 V AC line input.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 2711-TC4 |
| Brand | Allen-Bradley |
| Origin | Standard Industrial Manufacturing |
| Weight | 41.56 lbs (18.85 kg) |
| Dimensions | Standard PanelView 1200 Enclosure Cutout |
| Operating Temp | Standard Industrial Cabinet Limits |
| Power Consumption | 90-130 Volts Alternating Current |
| Display Size | 10.1 in. (12-inch class display assembly) |
| Display Color | Color |
| Input Type | Touchscreen (scratch-resistant chemically strengthened glass) |
| Communication | Remote I/O |
| Enclosure Type | NEMA 4X |
Profinet and EtherNet/IP Deterministic Network Integration
The terminal interfaces across industrial control networks to exchange tag data and operator control states via Remote I/O communication links. Its internal firmware flash and RAM memory architecture maintains screen application files and graphic objects, ensuring rapid execution of state changes and low communication latency across system backplane connections.
Frequently Asked Questions
Q: What structural considerations are required when mounting this 41.56 lbs terminal into an enclosure? A: Due to the 41.56 lbs weight, the panel cutout must be structurally reinforced to prevent metal flexing, and mounting clamps must be torqued evenly to maintain the NEMA 4X environmental seal.
Q: How does the Remote I/O communication port interface with the programmable logic controller? A: The Remote I/O link connects via standard blue hose cabling, allowing high-speed peer communication and multi-node data exchange with the host controller without requiring separate protocol converters.
Field Installation Guidelines
- Cut the panel mounting opening accurately according to PanelView 1200 specifications, verifying that the cabinet door or console can safely support the 41.56 lbs chassis load.
- Tighten all mounting brackets uniformly around the NEMA 4X bezel perimeter to compress the gasket seal and prevent moisture or dust ingress.
- Terminate AC power (90-130 V AC) and Remote I/O communication cables with proper shielding, routing signal lines away from high-voltage motor power leads.
Allen-Bradley 2711-TC4 PanelView 1200 Operator Terminal
Allen-Bradley 2711-TC4 PanelView 1200 Operator Terminal
TheAllen-Bradley 2711-TC4 , also cataloged as the 2711-TC4 PanelView 1200 Operator Terminal, operates as a dedicated hardware component for industrial process visualization and control input within Allen-Bradley PLC networks. It executes real-time graphic display rendering and touchscreen operator commands via a 10.1-inch color display utilizing Remote I/O communication protocols powered by 90-130 V AC line input.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 2711-TC4 |
| Brand | Allen-Bradley |
| Origin | Standard Industrial Manufacturing |
| Weight | 41.56 lbs (18.85 kg) |
| Dimensions | Standard PanelView 1200 Enclosure Cutout |
| Operating Temp | Standard Industrial Cabinet Limits |
| Power Consumption | 90-130 Volts Alternating Current |
| Display Size | 10.1 in. (12-inch class display assembly) |
| Display Color | Color |
| Input Type | Touchscreen (scratch-resistant chemically strengthened glass) |
| Communication | Remote I/O |
| Enclosure Type | NEMA 4X |
Profinet and EtherNet/IP Deterministic Network Integration
The terminal interfaces across industrial control networks to exchange tag data and operator control states via Remote I/O communication links. Its internal firmware flash and RAM memory architecture maintains screen application files and graphic objects, ensuring rapid execution of state changes and low communication latency across system backplane connections.
Frequently Asked Questions
Q: What structural considerations are required when mounting this 41.56 lbs terminal into an enclosure? A: Due to the 41.56 lbs weight, the panel cutout must be structurally reinforced to prevent metal flexing, and mounting clamps must be torqued evenly to maintain the NEMA 4X environmental seal.
Q: How does the Remote I/O communication port interface with the programmable logic controller? A: The Remote I/O link connects via standard blue hose cabling, allowing high-speed peer communication and multi-node data exchange with the host controller without requiring separate protocol converters.
Field Installation Guidelines
- Cut the panel mounting opening accurately according to PanelView 1200 specifications, verifying that the cabinet door or console can safely support the 41.56 lbs chassis load.
- Tighten all mounting brackets uniformly around the NEMA 4X bezel perimeter to compress the gasket seal and prevent moisture or dust ingress.
- Terminate AC power (90-130 V AC) and Remote I/O communication cables with proper shielding, routing signal lines away from high-voltage motor power leads.