Allen-Bradley 2711-T6C10L1 PanelView 600 Operator Interfaces
The Allen-Bradley 2711-T6C10L1, also cataloged as the 2711-T6C10L1 Operator Interface, operates as a dedicated hardware component for human-machine visualization and control input execution within DeviceNet and RS-232 serial networks.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 2711-T6C10L1 |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | 0.91 kg (2.01 lbs) |
| Dimensions | 152 mm x 185 mm x 82 mm (6.0 in. x 7.28 in. x 3.20 in.) |
| Operating Temp | 0 deg C to +55 deg C |
| Power Consumption | 24 W maximum (24 VDC nominal) |
| Supply Voltage | 18-32 VDC (24 VDC nominal) |
| Display Type | 5.7-inch Active Matrix TFT Color |
| Display Resolution | 320 x 234 pixels |
| Input Type | Analog Resistive Touchscreen |
| Communication Ports | DeviceNet Communication Port, RS-232 Printer Port |
| Internal Memory | 240 KB Application Flash Memory |
| Enclosure Rating | NEMA 12, 13, 4X (Indoor) / IP65 |
| Lifecycle Status | Discontinued by Manufacturer |
Backplane Bus Communication & Deterministic Network Interfacing
The Allen-Bradley 2711-T6C10L1 PanelView 600 terminal communicates across deterministic DeviceNet fieldbus channels to exchange real-time tag data, alarms, and setpoint updates directly with PLC-5, SLC 500, and ControlLogix processors. The onboard DeviceNet port supports explicit and I/O messaging profiles at communication velocities up to 500 Kbps. An independent RS-232 serial port enables asynchronous output for alarm printing and diagnostic logging. Internal firmware flash compatibility supports rapid application downloading via PanelBuilder32 software, maintaining deterministic cycle times and high I/O density scaling across distributed motor control centers and machine automation platforms.
Frequently Asked Questions
Q: What is the input supply voltage requirement for the 2711-T6C10L1 terminal?
A: The 2711-T6C10L1 requires a 24 VDC power supply operating within an allowable input range of 18 VDC to 32 VDC.
Q: Can the 2711-T6C10L1 touchscreen glass assembly be hot-swapped while power is applied?
A: No. Main 24 VDC control power and DeviceNet bus connections must be completely isolated before disconnecting or installing the terminal to prevent internal component damage and communication bus disruption.
Q: How is application runtime data preserved during a main power loss?
A: Application files, display screen graphics, and system parameters are saved directly to onboard nonvolatile flash memory, retaining configuration integrity without requiring a back-up battery during power outages.
Field Installation Guidelines
Prepare a rectangular panel cutout measuring 123 mm x 156 mm (4.86 in. x 6.15 in.) in a NEMA 4X or IP65 rated enclosure wall. Insert the 2711-T6C10L1 terminal through the front cutout, making sure the sealing gasket is correctly positioned around the outer bezel perimeter to maintain environmental ingress protection.
Secure the unit using the included mounting clips, tightening screws evenly in a cross pattern to a torque spec of 1.1 Nm to 1.4 Nm (10 in-lbs to 12 in-lbs). Connect the 24 VDC supply leads using copper conductors rated for at least 75 deg C, maintaining proper terminal polarity (+24 VDC and DC Common). Bond the terminal grounding lug to the main enclosure earth ground bar using a low-impedance grounding strap.
Allen-Bradley 2711-T6C10L1 PanelView 600 Operator Interfaces
Allen-Bradley 2711-T6C10L1 PanelView 600 Operator Interfaces
The Allen-Bradley 2711-T6C10L1, also cataloged as the 2711-T6C10L1 Operator Interface, operates as a dedicated hardware component for human-machine visualization and control input execution within DeviceNet and RS-232 serial networks.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 2711-T6C10L1 |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | 0.91 kg (2.01 lbs) |
| Dimensions | 152 mm x 185 mm x 82 mm (6.0 in. x 7.28 in. x 3.20 in.) |
| Operating Temp | 0 deg C to +55 deg C |
| Power Consumption | 24 W maximum (24 VDC nominal) |
| Supply Voltage | 18-32 VDC (24 VDC nominal) |
| Display Type | 5.7-inch Active Matrix TFT Color |
| Display Resolution | 320 x 234 pixels |
| Input Type | Analog Resistive Touchscreen |
| Communication Ports | DeviceNet Communication Port, RS-232 Printer Port |
| Internal Memory | 240 KB Application Flash Memory |
| Enclosure Rating | NEMA 12, 13, 4X (Indoor) / IP65 |
| Lifecycle Status | Discontinued by Manufacturer |
Backplane Bus Communication & Deterministic Network Interfacing
The Allen-Bradley 2711-T6C10L1 PanelView 600 terminal communicates across deterministic DeviceNet fieldbus channels to exchange real-time tag data, alarms, and setpoint updates directly with PLC-5, SLC 500, and ControlLogix processors. The onboard DeviceNet port supports explicit and I/O messaging profiles at communication velocities up to 500 Kbps. An independent RS-232 serial port enables asynchronous output for alarm printing and diagnostic logging. Internal firmware flash compatibility supports rapid application downloading via PanelBuilder32 software, maintaining deterministic cycle times and high I/O density scaling across distributed motor control centers and machine automation platforms.
Frequently Asked Questions
Q: What is the input supply voltage requirement for the 2711-T6C10L1 terminal?
A: The 2711-T6C10L1 requires a 24 VDC power supply operating within an allowable input range of 18 VDC to 32 VDC.
Q: Can the 2711-T6C10L1 touchscreen glass assembly be hot-swapped while power is applied?
A: No. Main 24 VDC control power and DeviceNet bus connections must be completely isolated before disconnecting or installing the terminal to prevent internal component damage and communication bus disruption.
Q: How is application runtime data preserved during a main power loss?
A: Application files, display screen graphics, and system parameters are saved directly to onboard nonvolatile flash memory, retaining configuration integrity without requiring a back-up battery during power outages.
Field Installation Guidelines
Prepare a rectangular panel cutout measuring 123 mm x 156 mm (4.86 in. x 6.15 in.) in a NEMA 4X or IP65 rated enclosure wall. Insert the 2711-T6C10L1 terminal through the front cutout, making sure the sealing gasket is correctly positioned around the outer bezel perimeter to maintain environmental ingress protection.
Secure the unit using the included mounting clips, tightening screws evenly in a cross pattern to a torque spec of 1.1 Nm to 1.4 Nm (10 in-lbs to 12 in-lbs). Connect the 24 VDC supply leads using copper conductors rated for at least 75 deg C, maintaining proper terminal polarity (+24 VDC and DC Common). Bond the terminal grounding lug to the main enclosure earth ground bar using a low-impedance grounding strap.