Allen-Bradley 2711-B6C8 PanelView 600 Standard Operator Terminal
The Allen-Bradley 2711-B6C8, also cataloged as the 2711-B6C8 Operator Interface, operates as a dedicated hardware component for human-machine visualization and dual keypad/touch input execution within Data Highway Plus (DH+) communication networks.
Suffix Breakdown & Model Matrix
| Base Model | Operator Input | Display Type | Primary Communication | Input Power |
|---|---|---|---|---|
| 2711-B6C8 | Keypad & Touchscreen | 5-inch Color TFT (320 x 240) | DH+ / RS-232 Printer Port | 100-240 VAC |
| 2711-B6C8L1 | Keypad & Touchscreen | 5-inch Color TFT (320 x 240) | DH+ / RS-232 Printer Port | 24 VDC |
| 2711-T6C8 | Touchscreen Only | 5-inch Color TFT (320 x 240) | DH+ / RS-232 Printer Port | 100-240 VAC |
| 2711-K6C8 | Keypad Only | 5-inch Color TFT (320 x 240) | DH+ / RS-232 Printer Port | 100-240 VAC |
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 2711-B6C8 |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | 2.06 kg (4.55 lbs) |
| Dimensions | 185 mm x 285 mm x 106 mm (7.28 in. x 11.22 in. x 4.17 in.) |
| Operating Temp | 0 deg C to +55 deg C |
| Power Consumption | 60 VA maximum (100-240 VAC nominal) |
| Supply Voltage | 85-264 VAC (100-240 VAC nominal) |
| Frequency | 47-63 Hz (50/60 Hz nominal) |
| Display Type | 5-inch Active Matrix Color TFT |
| Display Resolution | 320 x 240 pixels |
| Operator Input | Keypad (10 Function Keys) & Analog Resistive Touchscreen |
| Communication Ports | Data Highway Plus (DH+), RS-232 Printer Port |
| Application Memory | 170 KB Application RAM |
| Non-volatile Memory | 240 KB Application Flash |
| Enclosure Rating | NEMA 12, 13, 4X (Indoor) / IP65 |
| Lifecycle Status | Discontinued by Manufacturer |
Backplane Bus Communication & Deterministic Network Interfacing
The Allen-Bradley 2711-B6C8 PanelView 600 terminal communicates over multi-node Data Highway Plus (DH+) network trunks to maintain high-velocity deterministic data exchanges with PLC-5, SLC 500, and ControlLogix processors. Operating alongside an auxiliary RS-232 serial port for asynchronous alarm logging and report generation, the terminal offloads visualization processing from main CPU backplanes. Integrated firmware flash compatibility supports rapid screen downloads and firmware synchronization via PanelBuilder32 software, enabling deterministic scan times and high I/O density scaling across networked machine control cells.
Frequently Asked Questions
Q: What line power supply limits are required to operate the 2711-B6C8 terminal?
A: The 2711-B6C8 accepts a nominal input voltage of 100-240 VAC, functioning across an operational range of 85 VAC to 264 VAC at 47-63 Hz.
Q: Can the 2711-B6C8 terminal be disconnected or swapped while 100-240 VAC line power is energized?
A: No. Main AC supply power and DH+ network lines must be de-energized prior to terminal insertion or removal to prevent electrical contact arcing and communication bus disruption.
Q: How are screen graphics, alarm logs, and tag definitions retained when AC power is interrupted?
A: Application files, user setpoints, and display parameters are saved directly to 240 KB onboard nonvolatile flash memory, securing application code without requiring a back-up battery.
Field Installation Guidelines
Prepare a rectangular enclosure cutout measuring 167 mm x 264 mm (6.57 in. x 10.39 in.) in a NEMA 4X or IP65 rated panel wall. Mount the 2711-B6C8 terminal through the opening, ensuring the rubber sealing gasket sits flush against the panel outer surface.
Secure the terminal using the provided mounting clips, torque-tightening screws evenly in an alternating cross pattern to 1.1 Nm - 1.4 Nm (10 in-lbs - 12 in-lbs). Wire the 100-240 VAC power source using copper conductors rated for 75 deg C or higher, adhering to proper line, neutral, and earth terminals. Connect the DH+ 3-wire network cable (Belden 9463) to the 3-pin connector block, ensuring shield continuity, and bond the terminal grounding stud directly to the enclosure earth grounding bus with a low-impedance conductor.
Allen-Bradley 2711-B6C8 PanelView 600 Standard Operator Terminal
Allen-Bradley 2711-B6C8 PanelView 600 Standard Operator Terminal
The Allen-Bradley 2711-B6C8, also cataloged as the 2711-B6C8 Operator Interface, operates as a dedicated hardware component for human-machine visualization and dual keypad/touch input execution within Data Highway Plus (DH+) communication networks.
Suffix Breakdown & Model Matrix
| Base Model | Operator Input | Display Type | Primary Communication | Input Power |
|---|---|---|---|---|
| 2711-B6C8 | Keypad & Touchscreen | 5-inch Color TFT (320 x 240) | DH+ / RS-232 Printer Port | 100-240 VAC |
| 2711-B6C8L1 | Keypad & Touchscreen | 5-inch Color TFT (320 x 240) | DH+ / RS-232 Printer Port | 24 VDC |
| 2711-T6C8 | Touchscreen Only | 5-inch Color TFT (320 x 240) | DH+ / RS-232 Printer Port | 100-240 VAC |
| 2711-K6C8 | Keypad Only | 5-inch Color TFT (320 x 240) | DH+ / RS-232 Printer Port | 100-240 VAC |
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 2711-B6C8 |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | 2.06 kg (4.55 lbs) |
| Dimensions | 185 mm x 285 mm x 106 mm (7.28 in. x 11.22 in. x 4.17 in.) |
| Operating Temp | 0 deg C to +55 deg C |
| Power Consumption | 60 VA maximum (100-240 VAC nominal) |
| Supply Voltage | 85-264 VAC (100-240 VAC nominal) |
| Frequency | 47-63 Hz (50/60 Hz nominal) |
| Display Type | 5-inch Active Matrix Color TFT |
| Display Resolution | 320 x 240 pixels |
| Operator Input | Keypad (10 Function Keys) & Analog Resistive Touchscreen |
| Communication Ports | Data Highway Plus (DH+), RS-232 Printer Port |
| Application Memory | 170 KB Application RAM |
| Non-volatile Memory | 240 KB Application Flash |
| Enclosure Rating | NEMA 12, 13, 4X (Indoor) / IP65 |
| Lifecycle Status | Discontinued by Manufacturer |
Backplane Bus Communication & Deterministic Network Interfacing
The Allen-Bradley 2711-B6C8 PanelView 600 terminal communicates over multi-node Data Highway Plus (DH+) network trunks to maintain high-velocity deterministic data exchanges with PLC-5, SLC 500, and ControlLogix processors. Operating alongside an auxiliary RS-232 serial port for asynchronous alarm logging and report generation, the terminal offloads visualization processing from main CPU backplanes. Integrated firmware flash compatibility supports rapid screen downloads and firmware synchronization via PanelBuilder32 software, enabling deterministic scan times and high I/O density scaling across networked machine control cells.
Frequently Asked Questions
Q: What line power supply limits are required to operate the 2711-B6C8 terminal?
A: The 2711-B6C8 accepts a nominal input voltage of 100-240 VAC, functioning across an operational range of 85 VAC to 264 VAC at 47-63 Hz.
Q: Can the 2711-B6C8 terminal be disconnected or swapped while 100-240 VAC line power is energized?
A: No. Main AC supply power and DH+ network lines must be de-energized prior to terminal insertion or removal to prevent electrical contact arcing and communication bus disruption.
Q: How are screen graphics, alarm logs, and tag definitions retained when AC power is interrupted?
A: Application files, user setpoints, and display parameters are saved directly to 240 KB onboard nonvolatile flash memory, securing application code without requiring a back-up battery.
Field Installation Guidelines
Prepare a rectangular enclosure cutout measuring 167 mm x 264 mm (6.57 in. x 10.39 in.) in a NEMA 4X or IP65 rated panel wall. Mount the 2711-B6C8 terminal through the opening, ensuring the rubber sealing gasket sits flush against the panel outer surface.
Secure the terminal using the provided mounting clips, torque-tightening screws evenly in an alternating cross pattern to 1.1 Nm - 1.4 Nm (10 in-lbs - 12 in-lbs). Wire the 100-240 VAC power source using copper conductors rated for 75 deg C or higher, adhering to proper line, neutral, and earth terminals. Connect the DH+ 3-wire network cable (Belden 9463) to the 3-pin connector block, ensuring shield continuity, and bond the terminal grounding stud directly to the enclosure earth grounding bus with a low-impedance conductor.