Allen-Bradley 1769SC-IT6I Isolated Thermocouple Input Module
The 1769SC-IT6I is a six-point isolated thermocouple input module designed for temperature measurement in PLC-based control systems. It provides programmable thermocouple input capability, allowing a controller to acquire temperature signals from connected thermocouple sensors. The module is listed with UL/cUL and CE compliance and carries an ANSI/ISA 12.12.01 Class I, Division 2 hazardous-location classification.
Product Overview
The 1769SC-IT6I provides six thermocouple input points for temperature monitoring. Its isolated input configuration is intended to separate input measurement channels electrically, helping limit unwanted electrical interaction between connected measurement circuits.
The programmable input function supports configuration of the module for the required thermocouple measurement setup. The specific supported thermocouple types, temperature ranges, resolution, and conversion accuracy should be confirmed against the applicable manufacturer documentation before configuring the module.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | 1769SC-IT6I |
| Brand | Allen-Bradley |
| Product Type | Isolated Thermocouple Input Module |
| Input Type | Thermocouple |
| Number of Input Points | 6 |
| Input Configuration | Isolated |
| Configuration | Programmable |
| Safety Listing | UL/cUL Listed |
| Hazardous Location Classification | ANSI/ISA 12.12.01, Class I, Division 2, Groups A, B, C, D |
| Regulatory Compliance | CE |
| Weight | 0.47 lbs |
| Warranty | Radwell 2-year warranty included; factory warranty may not apply |
Input Configuration and Isolation
The six input points are intended for thermocouple-based temperature measurement. Input isolation is an important consideration when multiple temperature sensors operate under different electrical conditions, as it helps reduce the effects of electrical interference and unwanted signal interaction.
The programmable configuration allows the module to be set up for its supported measurement requirements. Confirm sensor compatibility and channel configuration before commissioning or replacing an existing module.
Certifications and Hazardous Location Classification
The supplied product information identifies UL/cUL listing and CE compliance. It also specifies ANSI/ISA 12.12.01 Class I, Division 2, Groups A, B, C, and D classification.
This classification relates to equipment suitability for specified hazardous locations. Actual installation suitability depends on the complete control system configuration and applicable installation requirements.
Frequently Asked Questions
Q: How many thermocouple inputs does the 1769SC-IT6I support?
A: The module provides six isolated thermocouple input points. The supported thermocouple types and measurement ranges should be checked against the applicable technical documentation.
Q: What does isolated input mean on the 1769SC-IT6I?
A: Input isolation provides electrical separation between measurement circuits, helping reduce unwanted electrical interaction between connected channels. The exact isolation arrangement and voltage ratings require confirmation from the module documentation.
Q: Is the 1769SC-IT6I suitable for hazardous locations?
A: The supplied specifications identify ANSI/ISA 12.12.01 Class I, Division 2, Groups A, B, C, and D classification. Installation must still comply with the applicable hazardous-location requirements and system configuration restrictions.
Allen-Bradley 1769SC-IT6I Isolated Thermocouple Input Module
Allen-Bradley 1769SC-IT6I Isolated Thermocouple Input Module
The 1769SC-IT6I is a six-point isolated thermocouple input module designed for temperature measurement in PLC-based control systems. It provides programmable thermocouple input capability, allowing a controller to acquire temperature signals from connected thermocouple sensors. The module is listed with UL/cUL and CE compliance and carries an ANSI/ISA 12.12.01 Class I, Division 2 hazardous-location classification.
Product Overview
The 1769SC-IT6I provides six thermocouple input points for temperature monitoring. Its isolated input configuration is intended to separate input measurement channels electrically, helping limit unwanted electrical interaction between connected measurement circuits.
The programmable input function supports configuration of the module for the required thermocouple measurement setup. The specific supported thermocouple types, temperature ranges, resolution, and conversion accuracy should be confirmed against the applicable manufacturer documentation before configuring the module.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | 1769SC-IT6I |
| Brand | Allen-Bradley |
| Product Type | Isolated Thermocouple Input Module |
| Input Type | Thermocouple |
| Number of Input Points | 6 |
| Input Configuration | Isolated |
| Configuration | Programmable |
| Safety Listing | UL/cUL Listed |
| Hazardous Location Classification | ANSI/ISA 12.12.01, Class I, Division 2, Groups A, B, C, D |
| Regulatory Compliance | CE |
| Weight | 0.47 lbs |
| Warranty | Radwell 2-year warranty included; factory warranty may not apply |
Input Configuration and Isolation
The six input points are intended for thermocouple-based temperature measurement. Input isolation is an important consideration when multiple temperature sensors operate under different electrical conditions, as it helps reduce the effects of electrical interference and unwanted signal interaction.
The programmable configuration allows the module to be set up for its supported measurement requirements. Confirm sensor compatibility and channel configuration before commissioning or replacing an existing module.
Certifications and Hazardous Location Classification
The supplied product information identifies UL/cUL listing and CE compliance. It also specifies ANSI/ISA 12.12.01 Class I, Division 2, Groups A, B, C, and D classification.
This classification relates to equipment suitability for specified hazardous locations. Actual installation suitability depends on the complete control system configuration and applicable installation requirements.
Frequently Asked Questions
Q: How many thermocouple inputs does the 1769SC-IT6I support?
A: The module provides six isolated thermocouple input points. The supported thermocouple types and measurement ranges should be checked against the applicable technical documentation.
Q: What does isolated input mean on the 1769SC-IT6I?
A: Input isolation provides electrical separation between measurement circuits, helping reduce unwanted electrical interaction between connected channels. The exact isolation arrangement and voltage ratings require confirmation from the module documentation.
Q: Is the 1769SC-IT6I suitable for hazardous locations?
A: The supplied specifications identify ANSI/ISA 12.12.01 Class I, Division 2, Groups A, B, C, and D classification. Installation must still comply with the applicable hazardous-location requirements and system configuration restrictions.