ABB|REU615|Protection and Control Relay
ABB REU615 Voltage Protection and Control Relay
Description
The ABB REU615 is a compact, withdrawable voltage protection and control relay from the Relion® 615 series, designed for utility and industrial power systems.
Features
- Voltage and frequency protection
- Automatic voltage regulation
- IEC 61850 communication support
- Local and Web HMI for control
- Optional arc protection and RTD/mA inputs
Technical Specifications
Protection Functions
- Three-phase overvoltage: 3 stages, 59 (PHPTOV)
- Three-phase undervoltage: 3 stages, 27 (PHPTUV)
- Residual overvoltage: 3 stages, 59G (ROVPTOV)
- Frequency protection: 6 stages, 81 (FRPFRQ)
- Load-shedding: 5 stages, 81LSH (LSHDPFRQ)
Control and Monitoring
- Circuit-breaker control: 1 instance (CBXCBR)
- Disconnector control: 2 instances (DCXSWI)
- Tap changer control: 1 instance, 90V (OLATCC)
- Trip circuit supervision: 2 instances (TCSSCBR)
- Disturbance recorder: 1 instance (RDRE)
Inputs/Outputs
- Analog inputs:
- 5 VT (Configuration A)
- 4 CT + 3 VT (Configuration B)
- Binary inputs:
- 12 (Configuration A)
- 14 (Configuration B)
- Binary outputs:
- 10 (Configuration A)
- 13 (Configuration B)
- RTD/mA inputs (optional, Configuration B):
- 6 RTD + 2 mA
Communication
- Protocols: IEC 61850, Modbus, DNP3, IEC 60870-5-103
- Ethernet: RJ-45 (100Base-TX), fiber-optic LC (100Base-FX)
- Time synchronization: IEEE 1588 v2
- Clients supported: 5 simultaneous
Hardware
- Display:
- Small (5 rows, 20 chars)
- Large (10 rows, 20 chars)
- LEDs: 11 programmable, red/green
- Power supply:
- 48–250 V DC
- 100–240 V AC
- 24–60 V DC
- Binary input threshold: 16–176 V DC
ABB|REU615|Protection and Control Relay
ABB|REU615|Protection and Control Relay
ABB REU615 Voltage Protection and Control Relay
Description
The ABB REU615 is a compact, withdrawable voltage protection and control relay from the Relion® 615 series, designed for utility and industrial power systems.
Features
- Voltage and frequency protection
- Automatic voltage regulation
- IEC 61850 communication support
- Local and Web HMI for control
- Optional arc protection and RTD/mA inputs
Technical Specifications
Protection Functions
- Three-phase overvoltage: 3 stages, 59 (PHPTOV)
- Three-phase undervoltage: 3 stages, 27 (PHPTUV)
- Residual overvoltage: 3 stages, 59G (ROVPTOV)
- Frequency protection: 6 stages, 81 (FRPFRQ)
- Load-shedding: 5 stages, 81LSH (LSHDPFRQ)
Control and Monitoring
- Circuit-breaker control: 1 instance (CBXCBR)
- Disconnector control: 2 instances (DCXSWI)
- Tap changer control: 1 instance, 90V (OLATCC)
- Trip circuit supervision: 2 instances (TCSSCBR)
- Disturbance recorder: 1 instance (RDRE)
Inputs/Outputs
- Analog inputs:
- 5 VT (Configuration A)
- 4 CT + 3 VT (Configuration B)
- Binary inputs:
- 12 (Configuration A)
- 14 (Configuration B)
- Binary outputs:
- 10 (Configuration A)
- 13 (Configuration B)
- RTD/mA inputs (optional, Configuration B):
- 6 RTD + 2 mA
Communication
- Protocols: IEC 61850, Modbus, DNP3, IEC 60870-5-103
- Ethernet: RJ-45 (100Base-TX), fiber-optic LC (100Base-FX)
- Time synchronization: IEEE 1588 v2
- Clients supported: 5 simultaneous
Hardware
- Display:
- Small (5 rows, 20 chars)
- Large (10 rows, 20 chars)
- LEDs: 11 programmable, red/green
- Power supply:
- 48–250 V DC
- 100–240 V AC
- 24–60 V DC
- Binary input threshold: 16–176 V DC