Honeywell|10310/1/1| Earth Leakage Detector (ELD) Module
HONEYWELL 10310/1/1 Earth Leakage Detector (ELD) Module
Description
HONEYWELL 10310/1/1 is an Earth Leakage Detector (ELD) module designed for 24 Vdc systems, providing reliable earth fault detection and monitoring.
Features
- Universal snap-in mounting for standard 35 mm DIN EN rails
- Manual self-test and earth connection monitor
- Selectable earth connection modes: DC, 1 Hz, or 0.25 Hz interruption
- Flip-flop latching upon earth fault with manual or external reset
- Integrated test function using internal 1.5 kOhm resistor
Technical Specifications
-
Power Supply
Voltage: 24 Vdc (max 30 Vdc)
Current: ≤ 60 mA -
Reset Input
Voltage: 18–70 Vdc
Current: 1.1 mA at 24 Vdc -
Earth Monitoring
Normal earth voltage: –12 Vdc
Earth fault voltage range: –30 to +70 Vdc
Fault threshold current: 5.5 mA ± 1 mA
Maximum earth current: 25.0 mA ± 5 mA -
Output Relay
Maximum contact voltage: 115 Vdc
Continuous current: 2 A
Initial contact resistance: 30 mΩ
Maximum switched load: 100 W / 1000 VA
Switching capacity: up to 250 Vdc / 250 Vac
Electrical life: 100,000 operations
Mechanical life: 200,000,000 operations -
Physical & Environmental
Dimensions: 70 × 45 × 110 mm (L × W × H)
Mounting: TS35 × 7.5 mm rail, max 46 mm length
Terminal torque: 1 Nm
Honeywell|10310/1/1| Earth Leakage Detector (ELD) Module
Honeywell|10310/1/1| Earth Leakage Detector (ELD) Module
HONEYWELL 10310/1/1 Earth Leakage Detector (ELD) Module
Description
HONEYWELL 10310/1/1 is an Earth Leakage Detector (ELD) module designed for 24 Vdc systems, providing reliable earth fault detection and monitoring.
Features
- Universal snap-in mounting for standard 35 mm DIN EN rails
- Manual self-test and earth connection monitor
- Selectable earth connection modes: DC, 1 Hz, or 0.25 Hz interruption
- Flip-flop latching upon earth fault with manual or external reset
- Integrated test function using internal 1.5 kOhm resistor
Technical Specifications
-
Power Supply
Voltage: 24 Vdc (max 30 Vdc)
Current: ≤ 60 mA -
Reset Input
Voltage: 18–70 Vdc
Current: 1.1 mA at 24 Vdc -
Earth Monitoring
Normal earth voltage: –12 Vdc
Earth fault voltage range: –30 to +70 Vdc
Fault threshold current: 5.5 mA ± 1 mA
Maximum earth current: 25.0 mA ± 5 mA -
Output Relay
Maximum contact voltage: 115 Vdc
Continuous current: 2 A
Initial contact resistance: 30 mΩ
Maximum switched load: 100 W / 1000 VA
Switching capacity: up to 250 Vdc / 250 Vac
Electrical life: 100,000 operations
Mechanical life: 200,000,000 operations -
Physical & Environmental
Dimensions: 70 × 45 × 110 mm (L × W × H)
Mounting: TS35 × 7.5 mm rail, max 46 mm length
Terminal torque: 1 Nm