Honeywell|MU-TAIH52|Field Termination Assembly
Description:
The Honeywell MU-TAIH52 is a High Level Analog Input/Smart Transmitter Interface (STI) Field Termination Assembly (FTA) designed for interfacing with 4-20 mA analog signals and Smart Transmitter devices.
Features:
- Interfaces with standard and Smart Transmitter signals.
- Provides accurate signal replication for safe area processing.
- Supports redundant Input/Output Processor (IOP) connectivity.
Technical Specifications:
-
Signal Input:
- Accepts 4-20 mA analog signals from transmitters.
- Compatible with Smart Transmitters with superimposed digital communications.
-
Signal Output:
- Provides 1-5 Vdc proportional to input signal for IOP processing.
- Auxiliary output available for monitoring or recording purposes.
-
Power Requirements:
- Operates on 24 Vdc from associated Power Distribution Assembly.
- Maximum power consumption: 1.28 A at 24 Vdc with 20 mA signal present.
-
Isolation:
- 250 Vac isolation between safe and hazardous sides.
-
Connectors:
- Equipped with screw-type terminal connectors for field wiring.
- 50-pin connector for IOP and auxiliary connections.
-
Environmental:
- Suitable for use in hazardous locations when properly installed.
- Complies with relevant safety standards for intrinsic safety.
Honeywell|MU-TAIH52|Field Termination Assembly



Honeywell|MU-TAIH52|Field Termination Assembly
Description:
The Honeywell MU-TAIH52 is a High Level Analog Input/Smart Transmitter Interface (STI) Field Termination Assembly (FTA) designed for interfacing with 4-20 mA analog signals and Smart Transmitter devices.
Features:
- Interfaces with standard and Smart Transmitter signals.
- Provides accurate signal replication for safe area processing.
- Supports redundant Input/Output Processor (IOP) connectivity.
Technical Specifications:
-
Signal Input:
- Accepts 4-20 mA analog signals from transmitters.
- Compatible with Smart Transmitters with superimposed digital communications.
-
Signal Output:
- Provides 1-5 Vdc proportional to input signal for IOP processing.
- Auxiliary output available for monitoring or recording purposes.
-
Power Requirements:
- Operates on 24 Vdc from associated Power Distribution Assembly.
- Maximum power consumption: 1.28 A at 24 Vdc with 20 mA signal present.
-
Isolation:
- 250 Vac isolation between safe and hazardous sides.
-
Connectors:
- Equipped with screw-type terminal connectors for field wiring.
- 50-pin connector for IOP and auxiliary connections.
-
Environmental:
- Suitable for use in hazardous locations when properly installed.
- Complies with relevant safety standards for intrinsic safety.