Honeywell|MU-TAMR02|Field Termination Assembly
Honeywell MU-TAMR02 Description
The Honeywell MU-TAMR02 is a Low Level Analog Input Multiplexer Field Termination Assembly (FTA) designed for processing low-level analog signals in industrial control systems.
Features
- Supports low-level analog input multiplexing
- Interfaces with thermocouples and other sensors
- CE compliant for European EMC and safety standards
- Optional conformal coating for harsh environments
Technical Specifications
Input Channels
- 16 differential input channels for low-level analog signals
- Supports thermocouple (TC) and resistive temperature device (RTD) inputs
Signal Compatibility
- Input range: ±100 mV for thermocouple inputs
- Cold Junction Reference (CJR) accuracy: ±0.5°C
Power Requirements
- Operating voltage: 24 Vdc
- Current consumption: 0.15 A at 24 Vdc
- Power dissipation: 3.6 W maximum
Environmental Specifications
- Operating temperature: 0°C to 60°C
- Storage temperature: -40°C to 85°C
- Relative humidity: 5% to 95% non-condensing
Isolation and Safety
- Isolation: 250 Vac between field and system side
- Safety compliance: CE marked, suitable for Division 2 hazardous locations
Physical Characteristics
- Dimensions: 145 mm (H) x 120 mm (W) x 50 mm (D)
- Weight: 0.5 kg
- Connector type: 50-pin for IOP interface
Honeywell|MU-TAMR02|Field Termination Assembly



Honeywell|MU-TAMR02|Field Termination Assembly
Honeywell MU-TAMR02 Description
The Honeywell MU-TAMR02 is a Low Level Analog Input Multiplexer Field Termination Assembly (FTA) designed for processing low-level analog signals in industrial control systems.
Features
- Supports low-level analog input multiplexing
- Interfaces with thermocouples and other sensors
- CE compliant for European EMC and safety standards
- Optional conformal coating for harsh environments
Technical Specifications
Input Channels
- 16 differential input channels for low-level analog signals
- Supports thermocouple (TC) and resistive temperature device (RTD) inputs
Signal Compatibility
- Input range: ±100 mV for thermocouple inputs
- Cold Junction Reference (CJR) accuracy: ±0.5°C
Power Requirements
- Operating voltage: 24 Vdc
- Current consumption: 0.15 A at 24 Vdc
- Power dissipation: 3.6 W maximum
Environmental Specifications
- Operating temperature: 0°C to 60°C
- Storage temperature: -40°C to 85°C
- Relative humidity: 5% to 95% non-condensing
Isolation and Safety
- Isolation: 250 Vac between field and system side
- Safety compliance: CE marked, suitable for Division 2 hazardous locations
Physical Characteristics
- Dimensions: 145 mm (H) x 120 mm (W) x 50 mm (D)
- Weight: 0.5 kg
- Connector type: 50-pin for IOP interface