Honeywell|900A01-0001|Analog Input Module
Honeywell ControlEdge HC900 900A01-0202 Universal Analog Input Module
Description
The Honeywell ControlEdge HC900 900A01-0202 is an 8-channel universal analog input module designed for the ControlEdge HC900 controller, offering support for multiple signal types with integrated galvanic isolation.
Features
- Supports thermocouple, RTD, mV, voltage, current, and slidewire inputs
- Provides point-to-point and backplane isolation
- Enables synchronous analog-to-digital conversion
- Includes LED indicators for module and channel diagnostics
Technical Specifications
- Inputs: 8 isolated analog channels
-
Input Types Supported:
- Thermocouple (B, E, J, K, etc.)
- RTD (100/500/1000 Pt, Cu10)
- mV (0–100 mV)
- Voltage (0–10 V)
- Current (4–20 mA)
- Slidewire (100–6500 ohms)
-
Input Impedance:
- 10 MΩ (T/C, mV)
-
1 MΩ (V)
- 250 Ω (mA)
-
Galvanic Isolation:
- 400 VDC point-to-point
- 1 kVDC from field to logic
-
Noise Rejection:
-
60 dB series mode
-
130 dB common mode at 120 VAC
-
-
Accuracy:
- ±0.1% of range (factory calibrated)
- ±0.05% (after field calibration) at 25°C ±3°C, 45–55% RH
- Cold Junction Accuracy: ±0.7°C
- Temperature Effect: ±0.01% full scale per °C
- A/D Resolution: 15 bits
- Update Rate: 500 ms
-
Power Supply Loading:
- 5 V, 40 mA max
- 24 V, 25 mA max
-
Burnout Detection:
- Configurable upscale/downscale or defined value (T/C, mV, V)
- Inherent upscale (RTD), downscale (mA)
-
Over-range Limit:
- ±10% (linear ranges)
- ±1% (non-linear ranges)
- Operating Temperature: 0°C to 60°C
- Storage Temperature: -40°C to 70°C
-
Relative Humidity:
- 10–90% non-condensing (operating)
- 5–95% (storage)
- Terminal Block: 20-pin Euro or Barrier style, tin/gold-plated contacts
- Dimensions: 137 mm H x 35.6 mm W x 66 mm D
- Weight: 210 g
Honeywell|900A01-0001|Analog Input Module


Honeywell|900A01-0001|Analog Input Module
Honeywell ControlEdge HC900 900A01-0202 Universal Analog Input Module
Description
The Honeywell ControlEdge HC900 900A01-0202 is an 8-channel universal analog input module designed for the ControlEdge HC900 controller, offering support for multiple signal types with integrated galvanic isolation.
Features
- Supports thermocouple, RTD, mV, voltage, current, and slidewire inputs
- Provides point-to-point and backplane isolation
- Enables synchronous analog-to-digital conversion
- Includes LED indicators for module and channel diagnostics
Technical Specifications
- Inputs: 8 isolated analog channels
-
Input Types Supported:
- Thermocouple (B, E, J, K, etc.)
- RTD (100/500/1000 Pt, Cu10)
- mV (0–100 mV)
- Voltage (0–10 V)
- Current (4–20 mA)
- Slidewire (100–6500 ohms)
-
Input Impedance:
- 10 MΩ (T/C, mV)
-
1 MΩ (V)
- 250 Ω (mA)
-
Galvanic Isolation:
- 400 VDC point-to-point
- 1 kVDC from field to logic
-
Noise Rejection:
-
60 dB series mode
-
130 dB common mode at 120 VAC
-
-
Accuracy:
- ±0.1% of range (factory calibrated)
- ±0.05% (after field calibration) at 25°C ±3°C, 45–55% RH
- Cold Junction Accuracy: ±0.7°C
- Temperature Effect: ±0.01% full scale per °C
- A/D Resolution: 15 bits
- Update Rate: 500 ms
-
Power Supply Loading:
- 5 V, 40 mA max
- 24 V, 25 mA max
-
Burnout Detection:
- Configurable upscale/downscale or defined value (T/C, mV, V)
- Inherent upscale (RTD), downscale (mA)
-
Over-range Limit:
- ±10% (linear ranges)
- ±1% (non-linear ranges)
- Operating Temperature: 0°C to 60°C
- Storage Temperature: -40°C to 70°C
-
Relative Humidity:
- 10–90% non-condensing (operating)
- 5–95% (storage)
- Terminal Block: 20-pin Euro or Barrier style, tin/gold-plated contacts
- Dimensions: 137 mm H x 35.6 mm W x 66 mm D
- Weight: 210 g