{"product_id":"allen-bradley-284d-fvd4p0z-10-cr-3-db-sb-oc-armorstart-284d-distributed-starter-series","title":"Série de arrancadores distribuídos ArmorStart 284D Allen-Bradley 284D-FVD4P0Z-10-CR-3-DB-SB-OC","description":"\u003cp\u003eConfigurado para o controlo da velocidade de motores CA de frequência variável e a execução de travagem dinâmica em redes de campo DeviceNet, o \u003cstrong\u003eAllen-Bradley 284D-FVD4P0Z-10-CR-3-DB-SB-OC\u003c\/strong\u003e (\u003cstrong\u003evariador de frequência 284D-FVD4P0Z\u003c\/strong\u003e) proporciona controlo físico\/elétrico direto de motores de indução trifásicos em linhas de processamento distribuído.\u003c\/p\u003e\n\u003ch3\u003eEspecificações do hardware\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelo\u003c\/td\u003e\n\u003ctd\u003e284D-FVD4P0Z-10-CR-3-DB-SB-OC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarca\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigem\u003c\/td\u003e\n\u003ctd\u003eEUA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e10.43 kg (23.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensões\u003c\/td\u003e\n\u003ctd\u003eFormato de caixa estanque ArmorStart 284D padrão\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura de funcionamento\u003c\/td\u003e\n\u003ctd\u003e-10 deg C a +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo de energia\u003c\/td\u003e\n\u003ctd\u003ePotência nominal de saída de 1.5 kW (2.0 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlimentação de controlo\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente nominal de saída\u003c\/td\u003e\n\u003ctd\u003e4.0 A a 1.5 kW (2.0 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacidade de curto-circuito\u003c\/td\u003e\n\u003ctd\u003eDispositivo com corrente nominal de 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface local\u003c\/td\u003e\n\u003ctd\u003eTeclado seletor Hand-Off-Auto (HOA) com função Jog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface de rede\u003c\/td\u003e\n\u003ctd\u003eAdaptador de protocolo DeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCaracterísticas do hardware\u003c\/td\u003e\n\u003ctd\u003eEntrada para conduta, conector de travão DB, contactor de travão da fonte, conector de saída\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eComunicação no barramento do backplane e interface de rede determinística\u003c\/h3\u003e\n\u003cp\u003eO Allen-Bradley 284D-FVD4P0Z-10-CR-3-DB-SB-OC estabelece uma interface direta com arquiteturas de controladores distribuídos através da sua porta de comunicação DeviceNet integrada, suportando redes determinísticas e elevada velocidade de comunicação em redes de campo. A compatibilidade com a memória flash do firmware permite a configuração rápida dos parâmetros do variador, mensagens de diagnóstico e atualizações remotas dos comandos de velocidade. O teclado Hand-Off-Auto integrado, com funcionalidade Jog, retira as substituições manuais de diagnóstico da lógica central do PLC, mantendo um controlo flexível e permitindo aumentar a densidade de E\/S de rede em maquinaria automatizada com vários eixos.\u003c\/p\u003e\n\u003ch3\u003ePerguntas frequentes\u003c\/h3\u003e\n\u003cp\u003eP: É possível desligar o variador 284D-FVD4P0Z-10-CR-3-DB-SB-OC do barramento DeviceNet enquanto a alimentação de controlo de 24 VDC está ativa?\u003c\/p\u003e\n\u003cp\u003eR: Não. As alimentações principais e a tensão de controlo de 24 VDC devem ser isoladas antes de efetuar a manutenção ou desligar os conectores de rede, para evitar arcos elétricos nos contactos e disparos de falhas de comunicação na rede DeviceNet.\u003c\/p\u003e\n\u003cp\u003eP: Que função desempenha o contactor de travão da fonte (SB) integrado neste modelo?\u003c\/p\u003e\n\u003cp\u003eR: O contactor de travão da fonte efetua a comutação elétrica direta para acionar um travão mecânico externo de retenção do motor, coordenando o bloqueio mecânico com as sequências de arranque\/paragem do variador.\u003c\/p\u003e\n\u003cp\u003eP: Como funciona o conector de travagem dinâmica (DB) durante a desaceleração do motor?\u003c\/p\u003e\n\u003cp\u003eR: O conector de travão DB estabelece a interface com uma resistência de travagem externa, permitindo que o transístor chopper interno desvie a energia elétrica regenerativa do barramento de CC durante ciclos de desaceleração rápida.\u003c\/p\u003e\n\u003ch3\u003eOrientações para a instalação em campo\u003c\/h3\u003e\n\u003cp\u003eMonte o variador verticalmente numa superfície plana e sólida ou na estrutura da máquina, utilizando as abas de montagem integradas. Mantenha uma distância livre mínima de 100 mm acima e abaixo do dissipador de calor para facilitar a convecção térmica natural sem obstruções.\u003c\/p\u003e\n\u003cp\u003ePasse os cabos de controlo de 24 VDC e as linhas de comunicação DeviceNet através de entradas para condutas dedicadas ou bucins de cabos blindados, mantendo os cabos de sinal separados dos condutores do motor CA trifásico. Certifique-se de que todos os conectores de saída de campo, ligações do travão DB e cabos do contactor do travão do motor estão devidamente apertados, de modo a manter a vedação ambiental e o alívio de tensão mecânica. Ligue diretamente o terminal de terra do chassis à terra principal da caixa, utilizando uma fita de cobre de baixa impedância.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelo\u003c\/td\u003e\n\u003ctd\u003e1794-TB3S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarca\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigem\u003c\/td\u003e\n\u003ctd\u003eEUA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e0.44 lbs (0.20 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensões\u003c\/td\u003e\n\u003ctd\u003eBase FLEX I\/O com dimensões padrão\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura de funcionamento\u003c\/td\u003e\n\u003ctd\u003e0 a 55 deg C (32 a 131 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo nominal de energia\u003c\/td\u003e\n\u003ctd\u003e125 VAC\/DC, máximo de 10 A através do barramento\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo de terminação\u003c\/td\u003e\n\u003ctd\u003eTerminal de mola\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminais de E\/S\u003c\/td\u003e\n\u003ctd\u003e16 terminais de E\/S (0-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminais comuns\u003c\/td\u003e\n\u003ctd\u003e18 terminais comuns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminais de tensão\u003c\/td\u003e\n\u003ctd\u003e18 terminais de +tensão\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCaixa \/ Montagem\u003c\/td\u003e\n\u003ctd\u003eModelo aberto, montado em calha DIN (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eComunicações no backplane e terminação de alta densidade\u003c\/h3\u003e\n\u003cp\u003eO 1794-TB3S proporciona interligação no backplane através de conectores de extremidade macho e fêmea integrados, permitindo a passagem contínua da alimentação do sistema e dos barramentos de dados de E\/S determinísticos entre bases FLEX I\/O adjacentes. O seu design de caixa de cablagem com terminais de mola mantém uma força de aperto contínua em ambientes sujeitos a vibrações elevadas, evitando o afrouxamento da cablagem de campo e as perdas de sinal. A compatibilidade com o barramento interno do backplane suporta a sincronização da memória flash do firmware e a inserção de módulos permutáveis em funcionamento (remoção e inserção sob tensão), sem interromper a comunicação do backplane entre ranhuras de E\/S adjacentes.\u003c\/p\u003e\n\u003ch3\u003ePerguntas frequentes\u003c\/h3\u003e\n\u003cp\u003eP: Quais são os requisitos relativos ao comprimento de descarnagem e à secção dos condutores para os terminais de mola?\u003c\/p\u003e\n\u003cp\u003eR: Os condutores de campo devem ser descarnados até 9.5 mm (0.37 in). Os terminais de mola aceitam fios de cobre sólidos ou entrançados com secções entre 0.33 e 2.5 mm sq (22 a 14 AWG), com uma temperatura nominal de 75 deg C ou superior.\u003c\/p\u003e\n\u003cp\u003eP: É possível inserir ou remover a base de terminais 1794-TB3S enquanto o backplane do sistema está energizado?\u003c\/p\u003e\n\u003cp\u003eR: Não. Embora os módulos digitais de E\/S ligados à base suportem a remoção e inserção sob tensão (RIUP), a própria base de terminais 1794-TB3S só deve ser instalada ou removida quando a alimentação do backplane e as fontes da cablagem de campo estiverem completamente isoladas, para evitar danos nos conectores provocados por arcos elétricos.\u003c\/p\u003e\n\u003cp\u003eP: Como é isolada a alimentação de campo entre bases 1794-TB3S adjacentes na mesma calha DIN?\u003c\/p\u003e\n\u003cp\u003eR: Os barramentos de alimentação da cablagem de campo (+V e Comum) passam através de jumpers de alimentação internos entre as bases. Para criar zonas de isolamento de alimentação separadas, o utilizador deve inserir uma chave de isolamento ou interromper a cadeia de jumpers de alimentação, conforme especificado na arquitetura de montagem do sistema FLEX I\/O.\u003c\/p\u003e\n\u003ch3\u003eOrientações para a instalação em campo\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMonte a calha DIN horizontalmente, assegurando a ligação adequada da calha à terra da placa traseira da caixa, para cumprir as normas de imunidade EMC.\u003c\/li\u003e\n\u003cli\u003eEncaixe a base de terminais 1794-TB3S na calha DIN, pressionando firmemente até o trinco de bloqueio engatar com segurança no rebordo da calha.\u003c\/li\u003e\n\u003cli\u003eDeslize a base firmemente para a esquerda, encaixando o seu conector de backplane no adaptador adjacente ou na unidade de base de terminais anterior.\u003c\/li\u003e\n\u003cli\u003eInsira uma chave de fendas pequena de ponta chata na ranhura de abertura do terminal de mola, introduza o condutor descarnado no orifício do fio e solte a chave de fendas para prender o fio.\u003c\/li\u003e\n\u003cli\u003eDefina o seletor de codificação do módulo na base para a posição necessária ao tipo específico de módulo de E\/S antes de inserir o cartão de E\/S ativo.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52836508270872,"sku":"284D-FVD4P0Z-10-CR-3-DB-SB","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/2711-B6C82_Cocoai.jpg?v=1791511859","url":"https:\/\/www.innoplcsync.com\/pt\/products\/allen-bradley-284d-fvd4p0z-10-cr-3-db-sb-oc-armorstart-284d-distributed-starter-series","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}