Description
- The HONEYWELL 900R12-0001 is a 12-slot I/O rack designed for the ControlEdge HC900 system, offering a scalable and robust platform for industrial process control applications.
Features
- Modular design for versatile I/O expansion.
- High-capacity slot configuration.
- Durable build for harsh industrial settings.
- Easy integration with ControlEdge HC900 controllers.
Technical Specifications
-
Physical Dimensions
- Width: 19.1 inches (485 mm).
- Height: 5.1 inches (130 mm).
- Depth: 8.8 inches (224 mm).
-
Capacity
- I/O slots: 12.
- Maximum I/O points: Up to 384 per rack (depending on module type).
-
Power Requirements
- Input voltage: 24 VDC.
- Power consumption: 20 W (base rack, excluding modules).
-
Environmental Conditions
- Operating temperature: 0°C to 60°C (32°F to 140°F).
- Storage temperature: -40°C to 85°C (-40°F to 185°F).
- Relative humidity: 5% to 95% (non-condensing).
-
Weight
- Approximate weight: 4.2 lbs (1.9 kg).
-
Mounting
- Compatible with DIN rail or panel mounting.
- Clearance required: 2 inches (50 mm) above and below for ventilation.
-
Certifications
- Meets CE, UL, and CSA standards for industrial use.
- Vibration resistance: 1G at 10-150 Hz per IEC 60068-2-6.
Honeywell|900R12-0001|12-Slot I/O Rack




Produto atual
Atual
Fornecedor:
Honeywell
Honeywell|900R12-0001|12-Slot I/O Rack
Preço regular
$100.00
Preço de venda
$100.00
Preço regular
$300.00
Opções
Descrições
Description
- The HONEYWELL 900R12-0001 is a 12-slot I/O rack designed for the ControlEdge HC900 system, offering a scalable and robust platform for industrial process control applications.
Features
- Modular design for versatile I/O expansion.
- High-capacity slot configuration.
- Durable build for harsh industrial settings.
- Easy integration with ControlEdge HC900 controllers.
Technical Specifications
-
Physical Dimensions
- Width: 19.1 inches (485 mm).
- Height: 5.1 inches (130 mm).
- Depth: 8.8 inches (224 mm).
-
Capacity
- I/O slots: 12.
- Maximum I/O points: Up to 384 per rack (depending on module type).
-
Power Requirements
- Input voltage: 24 VDC.
- Power consumption: 20 W (base rack, excluding modules).
-
Environmental Conditions
- Operating temperature: 0°C to 60°C (32°F to 140°F).
- Storage temperature: -40°C to 85°C (-40°F to 185°F).
- Relative humidity: 5% to 95% (non-condensing).
-
Weight
- Approximate weight: 4.2 lbs (1.9 kg).
-
Mounting
- Compatible with DIN rail or panel mounting.
- Clearance required: 2 inches (50 mm) above and below for ventilation.
-
Certifications
- Meets CE, UL, and CSA standards for industrial use.
- Vibration resistance: 1G at 10-150 Hz per IEC 60068-2-6.