{"product_id":"yokogawa-ssc60d-f2542-duplexed-safety-control-unit","title":"Yokogawa|SSC60D-F2542|Duplexed Safety Control Unit","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eYOKOGAWA SSC60D-F2542 Duplexed Safety Control Unit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDescription\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe YOKOGAWA SSC60D-F2542 is a Duplexed Safety Control Unit (SCU) for the ProSafe-RS Safety Instrumented System (SIS), providing dual-redundant fault-tolerant processing for SIL 3 certified safety applications\u003c\/span\u003e\u003ca href=\"https:\/\/www.automodulexpert.com\/products\/yokogawa-ssc60d-f2542-safety-control-unit\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.indctrlhub.com\/products\/yokogawa-ssc60d-f2542-safety-control-unit-dual-redundant-prosafe-rs\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSIL 3 certified per IEC 61508\u003c\/span\u003e\u003ca href=\"https:\/\/www.automodulexpert.com\/products\/yokogawa-ssc60d-f2542-safety-control-unit\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eDual-redundant MIPS R5000 processor architecture\u003c\/span\u003e\u003ca href=\"http:\/\/www.tek-international.com\/tek-international_Product_2014787564_Yokogawa-Duplexed-Safety-Control-Unit-SSC60D.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eDual-redundant Vnet\/IP and ESB bus interfaces\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/36097108\/yokogawa-ssc60-s--d-safety-control-unit-specification\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eRack mountable with wide temperature tolerance\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/36097108\/yokogawa-ssc60-s--d-safety-control-unit-specification\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eHot-swappable module support\u003c\/span\u003e\u003ca href=\"https:\/\/www.plcmasters.com\/products\/yokogawa-ssc60d-f2542-node-interface-module?variant=42877909499994\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eProcessor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMIPS R5000\u003c\/span\u003e\u003ca href=\"http:\/\/www.tek-international.com\/tek-international_Product_2014787564_Yokogawa-Duplexed-Safety-Control-Unit-SSC60D.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMain Memory:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e128 MB\u003c\/span\u003e\u003ca href=\"http:\/\/www.tek-international.com\/tek-international_Product_2014787564_Yokogawa-Duplexed-Safety-Control-Unit-SSC60D.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFunctional Safety:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSIL 3 certified (IEC 61508)\u003c\/span\u003e\u003ca href=\"https:\/\/www.automodulexpert.com\/products\/yokogawa-ssc60d-f2542-safety-control-unit\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eControl Cycle Time:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1 ms minimum\u003c\/span\u003e\u003ca href=\"https:\/\/www.automodulexpert.com\/products\/yokogawa-ssc60d-f2542-safety-control-unit\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCommunication Interfaces:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant Vnet\/IP (100 Mbps, 100Base-TX) and dual-redundant ESB bus\u003c\/span\u003e\u003ca href=\"http:\/\/www.tek-international.com\/tek-international_Product_2014787564_Yokogawa-Duplexed-Safety-Control-Unit-SSC60D.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Node Units:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUp to 13 via SEC402 ESB bus coupler with CFS1350 Node Expansion Package; up to 9 via SEC401 ESB bus coupler\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/36097108\/yokogawa-ssc60-s--d-safety-control-unit-specification\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/www.tek-international.com\/tek-international_Product_2014787564_Yokogawa-Duplexed-Safety-Control-Unit-SSC60D.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eI\/O Modules per SCU:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUp to 8\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/36097108\/yokogawa-ssc60-s--d-safety-control-unit-specification\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/www.tek-international.com\/tek-international_Product_2014787564_Yokogawa-Duplexed-Safety-Control-Unit-SSC60D.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eI\/O Capacity per SCS:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUp to 110 (with SEC402 + CFS1350); up to 78 (with SEC401)\u003c\/span\u003e\u003ca href=\"http:\/\/www.tek-international.com\/tek-international_Product_2014787564_Yokogawa-Duplexed-Safety-Control-Unit-SSC60D.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower Supply Options:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e100-120 V AC, 220-240 V AC, or 24 V DC\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/36097108\/yokogawa-ssc60-s--d-safety-control-unit-specification\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower Consumption (SSC60D-F):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e240 VA (100-120 V AC), 290 VA (220-240 V AC), 7.0 A (24 V DC)\u003c\/span\u003e\u003ca href=\"http:\/\/www.tek-international.com\/tek-international_Product_2014787564_Yokogawa-Duplexed-Safety-Control-Unit-SSC60D.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOperating Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to +70°C\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/36097108\/yokogawa-ssc60-s--d-safety-control-unit-specification\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 13.0 kg\u003c\/span\u003e\u003ca href=\"http:\/\/www.tek-international.com\/tek-international_Product_2014787564_Yokogawa-Duplexed-Safety-Control-Unit-SSC60D.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMounting:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e19-inch rack mount with twelve M5 screws\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52385721483544,"sku":"SSC60D-F2542","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/SSB401-53_2.jpg?v=1730429595","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-ssc60d-f2542-duplexed-safety-control-unit","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}