{"product_id":"yokogawa-nfsbt02-fio-node-baseplates","title":"YOKOGAWA NFSBT02 FIO Node Baseplates","description":"\u003cp\u003eConfigured for power routing and bus distribution in CENTUM VP and ProSafe-RS platforms, the \u003cstrong\u003eYokogawa NFSBT02\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNFSBT02\u003c\/strong\u003e FIO Node Baseplate, provides direct physical\/electrical execution. It serves as the electrical and mechanical foundation for Field I\/O (FIO) nodes, establishing system bus routing, module alignment, and centralized earthing across installed I\/O cards.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFSBT02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard FIO baseplate weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FIO node slot format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive backplane distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 I\/O modules per baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP DCS, ProSafe-RS SIS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eMechanical mounting and electrical backplane interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe NFSBT02 baseplate forms the passive backplane bus infrastructure that links Field I\/O modules directly to system controllers while maintaining high signal integrity. Integrated bus traces route dual-redundant FIO communications and power distribution rails directly to each module slot. Grounding planes constructed within the multilayer backplane assembly mitigate ground loops and high-frequency noise, preserving channel-to-channel isolation barriers and enabling transparent transmission of 4-20 mA HART analog signals from field instrumentation across the I\/O bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the NFSBT02 baseplate support online replacement or expansion of installed I\/O modules?\u003c\/p\u003e\n\u003cp\u003eA: Yes, when deployed within compatible CENTUM VP or ProSafe-RS system architectures, the NFSBT02 backplane bus supports hot-swapping of I\/O modules without requiring power interruption to the node or disturbing neighboring operational channels.\u003c\/p\u003e\n\u003cp\u003eQ: How does the NFSBT02 ensure noise immunity for low-level analog signal processing?\u003c\/p\u003e\n\u003cp\u003eA: The baseplate incorporates centralized internal grounding paths and dedicated power-plane shielding that prevent common-mode electrical noise and cross-talk from degrading sensitive analog signals passed between I\/O cards and the system bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the NFSBT02 baseplate securely to the enclosure DIN rail or mounting plate using the designated grounding standoffs to ensure a low-impedance earth path.\u003c\/li\u003e\n\u003cli\u003eVerify that all backplane power supply connections and FIO bus communication cables are firmly latched into their respective terminal blocks prior to energizing the node.\u003c\/li\u003e\n\u003cli\u003eDress low-voltage analog signal wiring away from high-voltage AC feed lines within cabinet wire ducts to preserve channel isolation and maintain overall system noise rejection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52608893223192,"sku":"NFSBT02","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/NFSB100-S50_1_b60a7554-ee7b-4f1e-b419-43c96c499d31.jpg?v=1788426069","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-nfsbt02-fio-node-baseplates","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}