{"product_id":"yokogawa-nfsb100-s00-bus-repeat-module","title":"Yokogawa NFSB100-S00 Bus Repeat Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa NFSB100-S00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNFSB100\u003c\/strong\u003e Bus Repeat Module, serves as the primary \u003cstrong\u003eNFSB100\u003c\/strong\u003e Bus Repeat Module utilized to execute signal regeneration and bus extension across CENTUM VP platforms. It receives internal bus communication signals from a local segment, regenerates degraded waveforms, and re-transmits them onto adjacent network segments to extend physical distance limits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFSB100-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm x 100 mm x 42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard bus-powered profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Type\u003c\/td\u003e\n\u003ctd\u003eProprietary Internal System Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eSignal Regeneration and Bus Extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe NFSB100-S00 integrates internal galvanic segment isolation to prevent ground loops and high-voltage line transients from propagating between interconnected bus branches. By isolating communication segments, the module maintains a noise-free data transport layer for upstream control stations and downstream I\/O units. This clean digital backplane environment prevents high-frequency bus interference from coupling into adjacent analog I\/O channels or disturbing sensitive 4-20 mA HART loop communication circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the signal regeneration process of the NFSB100-S00 introduce communication latency into the internal system bus?\u003c\/p\u003e\n\u003cp\u003eA: The module introduces a fixed, minimal propagation delay required for signal reshaping and galvanic isolation, designed to maintain deterministic response times across extended network topologies.\u003c\/p\u003e\n\u003cp\u003eQ: How does segment isolation inside the NFSB100-S00 protect the overall control network during a local electrical fault?\u003c\/p\u003e\n\u003cp\u003eA: Galvanic isolation barriers prevent physical short circuits, ground potential differences, or transient surge voltages on one bus branch from crossing onto adjacent segments or causing widespread network shutdown.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the NFSB100-S00 into its designated slot within the node chassis and confirm all physical latching clips engage securely.\u003c\/li\u003e\n\u003cli\u003eEnsure cabinet earthing bars are connected to a dedicated low-impedance instrument ground to maintain maximum noise suppression across extended bus lines.\u003c\/li\u003e\n\u003cli\u003eKeep high-voltage power lines and motor drive cables physically separated from the system bus cables entering and exiting the repeater module.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSAED5D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard chassis-mount footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial cabinet range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e10 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Resolution\u003c\/td\u003e\n\u003ctd\u003e20-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 5 MS\/s per channel (simultaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAggregate Sampling Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 10 MS\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O\u003c\/td\u003e\n\u003ctd\u003e16-bit digital inputs and outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Streaming Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 10 MS\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Storage\u003c\/td\u003e\n\u003ctd\u003eUp to 100 million data points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRemote control and monitoring via Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Modes\u003c\/td\u003e\n\u003ctd\u003eAnalog and digital triggering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh-Resolution Sampling \u0026amp; HART Loop Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 20-bit analog conversion architecture processes incoming field signals with channel-to-channel isolation to suppress high-frequency line noise and ground loops. Real-time high-speed data acquisition pipelines interface cleanly alongside standard 4-20 mA HART loop protocol lines, maintaining signal integrity across dense analog processing networks without cross-talk degradation or data frame corruption.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the SAED5D support simultaneous analog channel sampling?\u003c\/p\u003e\n\u003cp\u003eA: Yes. All 10 analog input channels feature dedicated conversion hardware enabling simultaneous sampling at rates up to 5 MS\/s per channel.\u003c\/p\u003e\n\u003cp\u003eQ: How is high-speed transient data managed onboard before network transmission?\u003c\/p\u003e\n\u003cp\u003eA: The board includes integrated onboard memory capable of storing up to 100 million data points for buffering high-speed burst acquisitions prior to Ethernet streaming.\u003c\/p\u003e\n\u003cp\u003eQ: What network interface is utilized for remote acquisition control and parameter setting?\u003c\/p\u003e\n\u003cp\u003eA: Remote control, data streaming, and hardware status monitoring are executed over a standard industrial Ethernet interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSecurely mount the SAED5D hardware module into the designated system enclosure frame, verifying all grounding tabs maintain firm metal-to-metal electrical contact.\u003c\/li\u003e\n\u003cli\u003eConnect field analog signal lines using shielded twisted-pair cables to preserve 20-bit measurement resolution and prevent high-frequency noise pickup.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields at the dedicated single-point cabinet ground rail rather than at the board terminals to eliminate potential ground loop paths.\u003c\/li\u003e\n\u003cli\u003eRoute industrial Ethernet cables away from high-voltage AC motor lines or inductive switching devices to prevent communication packet loss during 10 MS\/s data streaming.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52608893452568,"sku":"NFSB100-S00","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/NFSB100-S50_3_bbf1d391-6294-43a9-86c7-2e18385b4ca3.jpg?v=1788426074","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-nfsb100-s00-bus-repeat-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}