{"product_id":"yokogawa-nc2-c-dcs-network-communication-module","title":"Yokogawa NC2*C DCS Network Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa MX6*A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMX6A\u003c\/strong\u003e Interface Module, operates as a dedicated hardware component for analog and digital signal conditioning within Yokogawa DCS platforms. The unit bridges field instrumentation with system controllers by digitizing voltage, current, thermocouple, and RTD inputs over internal backplanes or fieldbus protocols.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMX6*A (MX6A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard DCS Module Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e170 x 70 x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Temperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem Backplane Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs Supported\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, Thermocouple, RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of reading for analog I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eYokogawa proprietary protocol, HART protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eInterface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MX6*A module features high-precision analog conditioning stages delivering continuous +\/-0.1% reading accuracy across multi-type sensor interfaces, including thermocouples and RTDs. Supported field channels accommodate 4-20 mA HART loop communication protocols, enabling pass-through of HART digital device diagnostics alongside standard analog signals to the DCS controller. Channel isolation networks shield the central processing core from high-voltage field spikes and earth loop currents.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What measurement accuracy does the MX6*A provide for analog input signals?\u003c\/p\u003e\n\u003cp\u003eA: The analog processing stage maintains an accuracy of +\/-0.1% of reading across supported voltage, current, thermocouple, and RTD inputs.\u003c\/p\u003e\n\u003cp\u003eQ: Does the MX6*A support smart transmitter digital diagnostics?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module interfaces with HART protocol field devices, enabling digital diagnostic and configuration data transfer to the host system.\u003c\/p\u003e\n\u003cp\u003eQ: What are the physical housing dimensions of the MX6*A interface hardware?\u003c\/p\u003e\n\u003cp\u003eA: The module measures 170 x 70 x 120 mm for insertion into compatible Yokogawa rack assemblies.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eAlign the MX6*A module with the mounting slot of the DCS backplane rack and push firmly until the locking mechanism latches.\u003c\/li\u003e\n\u003cli\u003eRoute signal wiring using twisted-pair cables, keeping low-mV thermocouple\/RTD lines separate from high-power AC conduits.\u003c\/li\u003e\n\u003cli\u003eTerminate individual cable shields at a single-point grounding bar to maintain signal integrity and reject common-mode noise.\u003c\/li\u003e\n\u003cli\u003eVerify HART loop power connections and field transmitter loop resistance prior to energizing the module.\u003c\/li\u003e\n\u003cli\u003eProvide sufficient panel enclosure spacing around the module assembly to ensure passive thermal dissipation within normal operating limits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52786771263768,"sku":"NC2*C","price":170.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/RB301S2_775e325f-33b6-4991-b4b2-5154caa162fe.png?v=1790649559","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-nc2-c-dcs-network-communication-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}