{"product_id":"yokogawa-fx1006-4-3-l-paperless-recorder","title":"Yokogawa FX1006-4-3-L Paperless Recorder","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa FX1006-4-3-L\u003c\/strong\u003e , also cataloged as the \u003cstrong\u003eFX1006\u003c\/strong\u003e Paperless Recorder, operates as a dedicated hardware component for multi-channel process variable measurement and data logging within Yokogawa automation architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFX1006-4-3-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e48.0 cm x 22.0 cm x 26.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100-120 VAC \/ 200 VPA, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5.7-inch color TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003eDCV, TC, RTD, DI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Interval\u003c\/td\u003e\n\u003ctd\u003e1 s, 125 ms (fast sampling)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e6 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Memory\u003c\/td\u003e\n\u003ctd\u003e400 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Storage\u003c\/td\u003e\n\u003ctd\u003eSD card \/ CF card (up to 32 GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05% of reading (DCV), +\/-0.15% of reading (TC, RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Signal Conditioning \u0026amp; Field Loop Protocol Features\u003c\/h3\u003e\n\u003cp\u003eThe FX1006-4-3-L incorporates high-precision analog-to-digital conversion circuitry designed to process mixed input signals including thermocouples, RTDs, and direct current voltage loops. Engineered with channel-to-channel isolation and integrated cold junction compensation (CJC) for thermocouple processing, the unit eliminates ground loops and noise pickup across multi-point measurement layouts. The unit buffers high-frequency process updates into internal non-volatile flash memory, enabling binary data storage and Ethernet network integration alongside standard 4-20 mA HART loop protocol instruments and DCS monitoring networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What primary signal types can be connected directly to the input terminals of the FX1006-4-3-L?\u003c\/p\u003e\n\u003cp\u003eA: The input channels natively support DC voltage (DCV), thermocouple (TC), resistance temperature detector (RTD), and contact\/discrete input (DI) signals.\u003c\/p\u003e\n\u003cp\u003eQ: How is data redundancy handled on the FX1006-4-3-L recorder?\u003c\/p\u003e\n\u003cp\u003eA: Process data is continuously logged to 400 MB of internal non-volatile memory and can be mirrored or exported to external SD\/CF media cards (up to 32 GB) or transferred via network connection.\u003c\/p\u003e\n\u003cp\u003eQ: What sampling speeds can be configured on this module?\u003c\/p\u003e\n\u003cp\u003eA: The unit supports a standard scan interval of 1 s as well as a fast sampling rate down to 125 ms for transient process capture.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure main cabinet power supply is de-energized before mounting the unit into a standard 19-inch rack cutout.\u003c\/li\u003e\n\u003cli\u003eRoute signal input leads separately from AC power lines and high-voltage relay wiring to prevent electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eGround the instrument panel chassis directly to earth ground using dedicated low-impedance grounding straps.\u003c\/li\u003e\n\u003cli\u003eVerify correct terminal screw torque and wiring polarity for thermocouple and RTD compensation leads to avoid measurement offsets.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52611936387352,"sku":"FX1006-4-3-L","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/FX1006-4-3-L_Cocoai_cb5dbf2a-8a45-4ec3-ac06-ab6baf54a441.jpg?v=1788513143","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-fx1006-4-3-l-paperless-recorder","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}