{"product_id":"yokogawa-f3yc08-0c-digital-output-module","title":"Yokogawa F3YC08-0C Digital Output Module","description":"\u003cp\u003eConfigured for discrete load actuation and relay contact switching in FA-M3 Range-free Multi-controller architectures, the \u003cstrong\u003eYokogawa F3YC08-0C\u003c\/strong\u003e ( \u003cstrong\u003eF3YC08\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution. It serves as the primary \u003cstrong\u003eF3YC08\u003c\/strong\u003e Digital Output Module utilized to execute relay signal control across Yokogawa PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3YC08-0C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e205 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FA-M3 I\/O Card Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane logic bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e8 independent relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n\u003ctd\u003e5-24 VDC \/ 100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e2 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Interface\u003c\/td\u003e\n\u003ctd\u003e18-point screw terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Signal Conditioning \u0026amp; Field Loop Protocol Features\u003c\/h3\u003e\n\u003cp\u003eThe F3YC08-0C relay output module provides mechanical galvanically-isolated contact paths between internal controller backplane logic and external field devices. Built with isolated commons across its 8 relay output channels, the module allows simultaneous switching of mixed AC and DC voltage supply rails. This isolated architecture prevents high-voltage switching transients and inductive noise from coupling into system backplane communications, supporting interlocking execution across discrete motor starters, solenoids, and standard 4-20 mA HART loop protocol instrument networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the F3YC08-0C output module support both AC and DC load voltage switching on the same card?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module features isolated commons allowing output channels to control both 5-24 VDC and 100-240 VAC loads across its 8 independent points.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current capacity per relay contact on the F3YC08-0C?\u003c\/p\u003e\n\u003cp\u003eA: Each individual relay output channel is rated for a maximum continuous load current of 2 A.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eTurn off all system base unit backplane power and external load power supplies prior to installing or removing the F3YC08-0C module.\u003c\/li\u003e\n\u003cli\u003eSeat the module edge connector into the FA-M3 base slot and secure the retention frame using M4 mounting screws.\u003c\/li\u003e\n\u003cli\u003eTerminate load wiring to the 18-point screw terminal block, ensuring correct torque is applied to terminal connections.\u003c\/li\u003e\n\u003cli\u003eInstall suppression devices (snubbers or flyback diodes) across external inductive loads to extend contact life and prevent high-voltage arcing.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52611940712728,"sku":"F3YC08-0C","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/F3YD64-1P_2__Cocoai_e8a1e5e7-8c8b-425e-9c01-61a019348874.png?v=1788513128","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-f3yc08-0c-digital-output-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}