{"product_id":"yokogawa-f3pu30-0s-power-supply-module","title":"Yokogawa F3PU30-0S Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa F3PU30-0S\u003c\/strong\u003e , also cataloged as the \u003cstrong\u003eF3PU30\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for primary system power conversion and backplane power distribution within Yokogawa FA-M3 Range-free Multi-controller platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3PU30-0S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FA-M3 Power Supply Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC (single-phase), 50\/60 Hz \/ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Fluctuation Range\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC, 50\/60 Hz +\/-3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e20 A max (120 VAC, Ta=25 deg C) \/ 45 A max (240 VAC, Ta=25 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Power Failure\u003c\/td\u003e\n\u003ctd\u003e20 ms momentary hold-up time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Signal Conditioning \u0026amp; Field Loop Protocol Features\u003c\/h3\u003e\n\u003cp\u003eThe F3PU30-0S power supply module incorporates internal isolation and voltage regulation logic to deliver continuous 5 VDC power to the FA-M3 backplane bus. Engineered with built-in noise filtering and surge suppression networks, the power stage prevents line transients and electromagnetic interference on the AC power mains from corrupting system memory and digital signal processing. The module maintains a 20 ms ride-through hold-up time during voltage sags, preserving CPU logic execution and system backplane communications across downstream 4-20 mA HART loop protocol instruments and digital I\/O nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the allowable input voltage fluctuation range for the F3PU30-0S?\u003c\/p\u003e\n\u003cp\u003eA: The module operates reliably within an extended input voltage range of 85 to 264 VAC at 50\/60 Hz (+\/-3 Hz).\u003c\/p\u003e\n\u003cp\u003eQ: How long can the F3PU30-0S sustain output power during a momentary main power supply interruption?\u003c\/p\u003e\n\u003cp\u003eA: The unit features an allowable momentary power failure time of up to 20 ms before the 5 VDC output rail drops out.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the main AC power distribution feeder is isolated and locked out before wiring line terminals to the F3PU30-0S input block.\u003c\/li\u003e\n\u003cli\u003eFasten the module securely into the designated left-most slot of the FA-M3 base unit to establish chassis ground contact.\u003c\/li\u003e\n\u003cli\u003eConnect dedicated protective earth (PE) grounding conductors directly to the unit's earth terminal using low-impedance cabling.\u003c\/li\u003e\n\u003cli\u003eAllow sufficient clearance around the power supply heat sink channels to ensure natural convection cooling during continuous high-load operation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52611940876568,"sku":"F3PU30-0S","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/F3PU30-0S_Cocoai.jpg?v=1788512960","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-f3pu30-0s-power-supply-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}