{"product_id":"yokogawa-f3cx04-0n-temperature-monitoring-module","title":"Yokogawa F3CX04-0N Temperature Monitoring Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa F3CX04-0N\u003c\/strong\u003e , also cataloged as the \u003cstrong\u003eF3CX04\u003c\/strong\u003e Temperature Monitoring Module, operates as a dedicated hardware component for multi-channel thermal data acquisition within Yokogawa FA-M3 Vitess series PLC architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3CX04-0N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard FA-M3 Module Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot FA-M3 I\/O Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane logic bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Sensors\u003c\/td\u003e\n\u003ctd\u003eThermocouples, RTDs, DC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Period\u003c\/td\u003e\n\u003ctd\u003e200 ms (all 4 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (photocouplers and transformers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Signal Conditioning \u0026amp; Cold Junction Compensation\u003c\/h3\u003e\n\u003cp\u003eThe F3CX04-0N incorporates advanced analog front-end isolation rated for 1500 VAC withstand voltage, utilizing photocouplers and transformers between input terminals and internal CPU backplane logic. Engineered for thermal measurement applications, the module supports universal inputs including thermocouples and RTDs with continuous cold junction compensation (CJC) processing. Onboard signal conditioning logic filters out high-frequency noise and ground loop transients across all 4 channels, allowing accurate thermal monitoring alongside 4-20 mA HART loop protocol instruments and high-density PLC control networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the input sampling refresh rate for temperature processing on the F3CX04-0N?\u003c\/p\u003e\n\u003cp\u003eA: The module executes complete input conversion and sampling across all four channels within a 200 ms scan period.\u003c\/p\u003e\n\u003cp\u003eQ: What level of electrical isolation is provided between the sensor field terminals and internal circuits?\u003c\/p\u003e\n\u003cp\u003eA: The module provides 1500 VAC isolation utilizing a combination of photocoupler and transformer barrier networks.\u003c\/p\u003e\n\u003cp\u003eQ: What alarm processing features are natively handled on individual channels?\u003c\/p\u003e\n\u003cp\u003eA: Each input channel supports up to 4 alarm points configurable for upper\/lower limit detection with selectable waiting functions and alarm ON-delay timing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the FA-M3 base chassis power supply is completely de-energized before inserting or unseating the F3CX04-0N module.\u003c\/li\u003e\n\u003cli\u003eTighten the single-slot module retaining screws securely to guarantee ground contact with the system base plate.\u003c\/li\u003e\n\u003cli\u003eWire thermocouple or RTD extension leads using shielded twisted-pair cables, grounding the cable shield drain wire directly at the cabinet earth bus bar.\u003c\/li\u003e\n\u003cli\u003eMaintain proper terminal separation for thermocouple compensating wires to avoid CJC reference temperature gradients across the terminal block.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52611941368088,"sku":"F3CX04-0N","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/F3LR02-0N_3__Cocoai.jpg?v=1788512938","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-f3cx04-0n-temperature-monitoring-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}