{"product_id":"yokogawa-asi133-s00-analog-input-module","title":"YOKOGAWA ASI133-S00 Analog Input Module","description":"\u003cp\u003eConfigured for analog current measurement and field telemetry ingestion in Yokogawa Centum CS and Centum VP platforms, the \u003cstrong\u003eYokogawa ASI133-S00\u003c\/strong\u003e ( \u003cstrong\u003eASI133\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASI133-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg (1.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32.0 mm x 133.0 mm x 146.0 mm (1.3 in x 5.3 in x 5.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied via rack backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Revision\u003c\/td\u003e\n\u003ctd\u003eStyle S-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM CS \/ CENTUM VP Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation Integration\u003c\/h3\u003e\n\u003cp\u003eThe ASI133-S00 analog input module conditions process variable signals from field instruments, converting continuous analog current measurements into digitized process values for CPU execution. Internal channel-to-channel isolation networks block common-mode voltage spikes, preventing noise cross-talk between adjacent field circuits. The input architecture maintains continuous signal conversion for connected 4-20 mA HART loop protocol transmitters, ensuring accurate data update cycles and system stability across CENTUM VP I\/O backplanes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What primary function does the ASI133-S00 module execute within a CENTUM VP node?\u003c\/p\u003e\n\u003cp\u003eA: The ASI133-S00 functions as an Analog Input Module, digitizing current signals from field transmitters and routing process telemetry to the host Field Control Unit across the backplane.\u003c\/p\u003e\n\u003cp\u003eQ: Are backplane connectors hot-swappable during module replacement?\u003c\/p\u003e\n\u003cp\u003eA: While CENTUM VP hardware supports online module replacement, engineers should verify redundant I\/O configurations and follow proper rack ESD grounding steps prior to pulling or seating the card.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eShut down field loop power supplies and verify power isolation before servicing or removing the module.\u003c\/li\u003e\n\u003cli\u003eGround all anti-static equipment by attaching a grounding wrist strap to the bare metal surface of the control cabinet.\u003c\/li\u003e\n\u003cli\u003eAlign the circuit board edges with the module slot guides inside the chassis and insert the assembly until the backplane contacts engage.\u003c\/li\u003e\n\u003cli\u003eSecure the top and bottom mounting screws on the front panel to provide chassis frame grounding and mechanical stability against vibration.\u003c\/li\u003e\n\u003cli\u003eTerminate all incoming analog input cable shields to the protective earth ground bar, keeping unshielded wire runs as short as possible to prevent signal degradation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52626188468504,"sku":"ASI133-S00","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/ASI133-S00_3.png?v=1788773671","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-asi133-s00-analog-input-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}