{"product_id":"yokogawa-and50-562-interface-card","title":"Yokogawa AND50-562 Interface Card","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AND50-562\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAND50\u003c\/strong\u003e Interface Card, operates as a dedicated hardware component for I\/O expansion and RIO bus connectivity within dual-redundant DCS architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAND50-562\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm (L) x 120 mm (W) x 25 mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in source data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eRIO bus protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O Points\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Standard\u003c\/td\u003e\n\u003ctd\u003e19-inch Rack or DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRIO Bus Protocol and Dual-Redundant Architecture\u003c\/h3\u003e\n\u003cp\u003eThis interface card executes data transfer across the RIO (Remote I\/O) bus protocol, specifically configured for dual-redundant system topologies. The dual-redundant RIO bus architecture provides two independent physical communication paths between the central controller and the remote I\/O node. Data integrity is maintained through continuous synchronization between the primary and secondary bus segments. The card provides 16 digital I\/O points and 8 analog I\/O points, supporting both signal acquisition and control output execution. Channel-to-channel isolation prevents ground loop interference between analog and digital signal domains. The 24 VDC power supply requirement aligns with standard industrial control power distribution infrastructure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum operating temperature for the AND50-562 interface card?\u003cbr\u003eA: The AND50-562 operates within a temperature range of -20 deg C to +60 deg C. Operation outside this range requires environmental conditioning or derating.\u003c\/p\u003e\n\u003cp\u003eQ: Can this card be installed in a non-redundant RIO bus configuration?\u003cbr\u003eA: The AND50-562 is designed for dual-redundant RIO bus systems. Installation in non-redundant configurations may not provide expected performance characteristics. Consult the system hardware manual for compatibility verification.\u003c\/p\u003e\n\u003cp\u003eQ: What is the I\/O point density of this interface card?\u003cbr\u003eA: The AND50-562 provides 16 digital I\/O points and 8 analog I\/O points per card. Total I\/O capacity depends on the number of cards installed in the node unit.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the AND50-562 in a 19-inch rack or on DIN rail per the mechanical specifications. Ensure adequate ventilation clearance around the card to maintain operating temperature within -20 deg C to +60 deg C limits. Connect the 24 VDC power supply with proper polarity protection. Route RIO bus cables in shielded twisted-pair configuration with the shield grounded at one end only to prevent ground loops. Verify dual-redundant bus connections are properly terminated at both ends of each bus segment. Confirm all I\/O wiring matches the channel assignment table before applying power. Perform continuity testing on all digital I\/O circuits and loop calibration on analog channels prior to commissioning.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52634812514584,"sku":"AND50-562","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/ANB10D-4213_Cocoai_3223bfa1-4e27-46b8-abf3-8a6f31bb3296.jpg?v=1788860522","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-and50-562-interface-card","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}