{"product_id":"yokogawa-anb10d-410-ndel-dual-redundant-esb-bus-node-unit","title":"Yokogawa ANB10D-410\/NDEL Dual-Redundant ESB Bus Node Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB10D-410\/NDEL\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eANB10D\u003c\/strong\u003e Dual-Redundant ESB Bus Node Unit, operates as a dedicated hardware component for high-speed analog signal acquisition and deterministic data link management within CENTUM VP control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-410\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 53 mm (W) x 110 mm (H) x 170 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC, 1-5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Limits\u003c\/td\u003e\n\u003ctd\u003e27 mA \/ +\/-7.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-16 uA or +\/-4 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep Response Time\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e400 ohm (at 20 mA) to 1000 ohm (at 4 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA Loop Processing and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-410\/NDEL processes 16 differential analog field signals using a 10 ms deterministic data update period to ensure zero-latency synchronization with the master Field Control Station (FCS). Variable input resistance characteristics (400 ohm at 20 mA to 1000 ohm at 4 mA) maintain signal conditioning stability across standard current loop transmitters. Integrated galvanic channel isolation prevents ground potential offsets from degrading analog measurement accuracy or inducing signal crosstalk across process control loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the dual-redundant architecture of the ANB10D-410\/NDEL allow hot-swapping under powered conditions?\u003c\/p\u003e\n\u003cp\u003eA: Yes, individual I\/O modules and node interface cards mounted on the unit can be replaced while powered. The dual ESB bus interface maintains live communication over the secondary line during hot-swap procedures without disturbing active loop outputs.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions should be taken regarding allowable input current limits?\u003c\/p\u003e\n\u003cp\u003eA: Input currents must not exceed the maximum rating of 27 mA DC (or voltage limits of +\/-7.5 V). Sustained current overloads above this threshold can trigger internal protection thermal fuses or degrade accuracy specs beyond the standard +\/-16 uA limit.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that external 24 VDC supply voltage remains within the allowable tolerance range of 21.6 VDC to 26.4 VDC before energizing the rack assembly.\u003c\/li\u003e\n\u003cli\u003eGround all field cable shields to a dedicated instrumentation earth bar at a single termination point to avoid ground loop current interference.\u003c\/li\u003e\n\u003cli\u003eMaintain separate wiring ducts for 4-20 mA analog signal cables and high-voltage AC power distribution lines to minimize electromagnetic induction.\u003c\/li\u003e\n\u003cli\u003eTorque all terminal block landing screws to manufacturer-specified limits to ensure low-resistance physical wire contact and prevent thermal hot spots.\u003c\/li\u003e\n\u003cli\u003eConfirm that cabinet cooling fan assemblies provide continuous positive airflow to keep ambient temperatures within the -20 to +60 deg C operating window.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52634861437208,"sku":"ANB10D-410\/NDEL","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/ANB10D-4213_Cocoai_07349530-5c3e-4941-86c3-f03533ee1ac2.jpg?v=1788860579","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-anb10d-410-ndel-dual-redundant-esb-bus-node-unit","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}