{"product_id":"yokogawa-adv551-p50-digital-output-module","title":"Yokogawa ADV551-P50 Digital Output Module","description":"\u003cp\u003eConfigured for pulse-width and time-proportional output generation in CENTUM VP control systems, the \u003cstrong\u003eYokogawa ADV551-P50\u003c\/strong\u003e (\u003cstrong\u003eADV551\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code 1\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code 2\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code 3\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADV551\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePulse-width output \/ time-proportional output function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADV551\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout status display; with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADV551\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type hardware design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Format\u003c\/td\u003e\n\u003ctd\u003eCurrent sink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e3 ms or less (status output); 10 ms or less (mixed status and pulse outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Range\u003c\/td\u003e\n\u003ctd\u003e8 ms to 7200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Resolution\u003c\/td\u003e\n\u003ctd\u003e8 ms (with maximum ON\/OFF delay addition of 1 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage (System Isolation)\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute between output signal and system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage (Common Isolation)\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute between commons (common minus side every 16 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Interface Adapter\u003c\/td\u003e\n\u003ctd\u003eModel ATD5A-00 (32-channel digital interface adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and DCS Integration\u003c\/h3\u003e\n\u003cp\u003eThe ADV551-P50 current-sink output module utilizes galvanic channel-to-system isolation rated for 2 kV AC over 1 minute to prevent ground loop noise from propagating to system backplane logic. Output points are arranged in isolated banks with 500 V AC dielectric strength maintained between common negative rails every 16 channels. Dedicated hardware timers manage pulse-width actuation independently, maintaining consistent signal switching down to 8 ms resolutions across 4-20 mA HART loops and discrete DCS execution networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the dielectric isolation rating between common minus connections on the ADV551-P50?\u003c\/p\u003e\n\u003cp\u003eA: The module maintains a withstanding voltage rating of 500 V AC for 1 minute between common minus (-) sides configured every 16 channels.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum signal timing response for mixed status and pulse outputs?\u003c\/p\u003e\n\u003cp\u003eA: The output response time is rated at 10 ms or less when operating in mixed status and pulse modes, and 3 ms or less for pure status outputs.\u003c\/p\u003e\n\u003cp\u003eQ: Does the ADV551-P50 model include front-panel status display LEDs?\u003c\/p\u003e\n\u003cp\u003eA: No, per Suffix Code 2 position 5, this model variant is supplied without a front-panel status display and without explosion protection.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the backplane slot keys and turn off cabinet field power before inserting the module into the I\/O node chassis.\u003c\/li\u003e\n\u003cli\u003eAlign the ATD5A-00 interface adapter with the front connector port and secure retaining screws to ensure proper electrical contact.\u003c\/li\u003e\n\u003cli\u003eWire external DC loads using current-sinking polarity, ensuring the external power supply stays strictly within the 20.4 to 26.4 VDC operating envelope.\u003c\/li\u003e\n\u003cli\u003eRoute 24 VDC signal wiring away from high-voltage AC conductors to prevent capacitive noise coupling into pulse-width loops.\u003c\/li\u003e\n\u003cli\u003eEarth all cable shields at the single-point cabinet grounding bus according to Yokogawa DCS installation practices.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52640830587160,"sku":"ADV151-P50","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/VC401-10_2_2a644875-456c-4699-b463-d36813343e57.jpg?v=1789005785","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-adv551-p50-digital-output-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}