{"product_id":"yokogawa-adv151-e50-d5a00-input-module","title":"Yokogawa ADV151-E50\/D5A00 Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV151-E50\/D5A00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for high-speed sequence-of-events status monitoring within CENTUM VP DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Catalog Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Description \/ Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADV151\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-E50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\/D5A00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32-Channel 24 VDC Isolated DI Module (With SOE Capture, Standard Bezel, KS Cable Adapter ATD5A-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADV151\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-E60\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\/D5A00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32-Channel 24 VDC Isolated DI Module (With SOE Capture, LED Status Display, KS Cable Adapter ATD5A-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADV151\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-P00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-S2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32-Channel Standard Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-E50\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg (0.66 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CENTUM VP I\/O Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C (32 to 122 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e350 mA max @ 5 VDC system bus draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e32 Channels (Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSequence of Events (SOE)\u003c\/td\u003e\n\u003ctd\u003eIntegrated SOE event time-stamping capture capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Withstanding Voltage\u003c\/td\u003e\n\u003ctd\u003eInput-to-System: 2 kV AC for 1 min; Between Commons: 500 V AC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Interface Adapter\u003c\/td\u003e\n\u003ctd\u003e\/D5A00 (Model ATD5A-00 KS Cable Interface Adapter for 32 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.50 kg (3.30 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and DCS Fieldbus Integration\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-E50\/D5A00 incorporates channel-to-channel isolation and 2 kV AC dielectric withstand ratings between field input circuits and the system backplane to eliminate ground loops. The onboard Sequence of Events (SOE) processing unit timestamps discrete input transition events at sub-millisecond precision directly at the module layer before transferring digitized event records across the Vnet\/IP deterministic network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the suffix code -E50 on the ADV151 module support Sequence of Events (SOE) time-stamping?\u003c\/p\u003e\n\u003cp\u003eA: Yes, suffix code -E indicates the inclusion of dedicated hardware circuit blocks for high-precision SOE event capture.\u003c\/p\u003e\n\u003cp\u003eQ: What interface adapter is supplied with the option code \/D5A00?\u003c\/p\u003e\n\u003cp\u003eA: Option \/D5A00 includes the ATD5A-00 KS cable interface adapter designed to interface 32 discrete input channels via standardized KS multi-conductor cables.\u003c\/p\u003e\n\u003cp\u003eQ: What is the isolation withstand voltage between field signal wiring and the DCS backplane?\u003c\/p\u003e\n\u003cp\u003eA: Galvanic optical isolation provides 2 kV AC dielectric insulation for 1 minute between output\/input field signals and the system backplane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure target node chassis backplane slot power is disconnected prior to inserting or removing the ADV151 module.\u003c\/li\u003e\n\u003cli\u003eAlign module card edge guides with the slot rails and press firmly until top and bottom mechanical lock levers lock into position.\u003c\/li\u003e\n\u003cli\u003eFasten the ATD5A-00 adapter block onto the front connector face and tighten retaining screws to specified torque limits.\u003c\/li\u003e\n\u003cli\u003eRoute 24 VDC field contact sensing lines in dedicated raceways separated from high-voltage AC power lines to mitigate capacitive cross-talk.\u003c\/li\u003e\n\u003cli\u003eTerminate overall field cable drain wires directly to the cabinet low-impedance frame ground (FG) bar following standard Yokogawa installation rules.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52640830619928,"sku":"ADV151-E50\/D5A00","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/VC401-10_3_ba841cd9-5692-4746-ba1b-f0518e404c76.jpg?v=1789005797","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-adv151-e50-d5a00-input-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}