{"product_id":"yokogawa-adm51c-2-contact-output-module","title":"Yokogawa ADM51C-2 Contact Output Module","description":"\u003cp\u003eConfigured for discrete load switching and pulse generation in CENTUM CS 3000 and CENTUM CS 1000 systems, the \u003cstrong\u003eYokogawa ADM51C-2\u003c\/strong\u003e (\u003cstrong\u003eADM51C\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Catalog Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Description \/ Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADM51C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e--\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-Point Transistor Contact Output Module (Standard Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADM51C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e--\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-Point Relay Contact Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADM51C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\/D5A00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-Point Transistor Contact Output Module with KS Cable Adapter Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADM51C-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CENTUM CS 3000 \/ CS 1000 I\/O Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e600 mA max at 5.0 VDC system bus draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Type\u003c\/td\u003e\n\u003ctd\u003eTransistor contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating (Resistive)\u003c\/td\u003e\n\u003ctd\u003e30 VDC, 100 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating (Inductive)\u003c\/td\u003e\n\u003ctd\u003e30 VDC, 100 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 7200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Resolution\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and DCS Integration\u003c\/h3\u003e\n\u003cp\u003eThe ADM51C-2 module features solid-state transistor switching logic that isolates field load currents from system backplane processing circuits. Hardware-timed pulse duration capabilities ranging from 0.1 to 7200 s offload low-level timing execution from central CPU nodes. Operating within 4-20 mA HART loop and DCS signal interface architectures, the 16 output channels maintain precise switching routines down to a 20 ms pulse resolution without inducing software latency on the system control bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the voltage and current limits for field loads connected to the ADM51C-2?\u003c\/p\u003e\n\u003cp\u003eA: The transistor output contacts are rated for resistive and inductive loads up to 30 VDC at 100 mA or less per point.\u003c\/p\u003e\n\u003cp\u003eQ: What is the backplane power supply current draw for this module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a maximum current of 600 mA from the internal 5.0 VDC system power rail.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum programmable pulse duration and resolution on the ADM51C-2?\u003c\/p\u003e\n\u003cp\u003eA: Pulse width is adjustable from 0.1 to 7200 s with a timing resolution of 20 ms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the I\/O rack backplane before inserting or removing the ADM51C-2 module.\u003c\/li\u003e\n\u003cli\u003eAlign the module circuit board with the chassis slot rails and push firmly until the mounting latch locks into place.\u003c\/li\u003e\n\u003cli\u003eWire external DC loads in series with transistor outputs, verifying that voltage and current remain strictly below 30 VDC and 100 mA.\u003c\/li\u003e\n\u003cli\u003eInstall flyback suppression diodes across inductive loads to prevent back-EMF voltage spikes from damaging the solid-state outputs.\u003c\/li\u003e\n\u003cli\u003eConnect cable drain shields directly to the cabinet ground bar according to standard Yokogawa DCS installation practices.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52640831078680,"sku":"ADM51C-2","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/ADM51C-2_Cocoai.jpg?v=1789005807","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-adm51c-2-contact-output-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}