{"product_id":"yokogawa-7m190-ydm05-centum-vp-input-module","title":"Yokogawa 7M190-YDM05 CENTUM VP Input Module","description":"\u003cp\u003eConfigured for high-resolution signal capture in industrial automation networks, the \u003cstrong\u003eYokogawa 7M190-YDM05\u003c\/strong\u003e (\u003cstrong\u003e7M190-YDM05\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. It processes 16 analog input channels across a -10 to +10 VDC input range with 16-bit resolution and 1500 VAC channel isolation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e7M190-YDM05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e150 mm x 100 mm x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+-0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and CJC Loop Integration\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates 1500 VAC galvanic isolation barriers to prevent ground loops and high common-mode voltage transients from propagating across individual channels. The 16-bit analog-to-digital conversion architecture maintains signal linearity across the -10 to +10 VDC input range. When interfacing thermocouples or specialized transducers, cold junction compensation (CJC) handling and signal conditioning circuits stabilize measurement accuracy against ambient temperature fluctuations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the input power requirements for the 7M190-YDM05 module?\u003c\/p\u003e\n\u003cp\u003eA: The module requires an external 24 VDC input supply, drawing approximately 50 mA of operational current during active signal acquisition.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle high common-mode voltages between field sensors and the control system?\u003c\/p\u003e\n\u003cp\u003eA: The 1500 VAC isolation barrier between the field inputs and internal logic circuitry isolates common-mode disturbances, preventing signal corruption across adjacent channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module onto the designated DIN rail or system rack, ensuring secure mechanical locking before engaging backplane electrical connectors.\u003c\/li\u003e\n\u003cli\u003eTerminate -10 to +10 VDC analog signal wiring using shielded twisted-pair cables, grounding the shield drain wire at a single marshalling panel earth stud to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the 24 VDC supply voltage remains stable within operating limits prior to energizing the module.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52842860085528,"sku":"7M190-YDM05","price":170.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/ADV561-P00-S22_Cocoai_eedf08d8-b82a-4853-88be-7b8a60d60c09.jpg?v=1791596937","url":"https:\/\/www.innoplcsync.com\/products\/yokogawa-7m190-ydm05-centum-vp-input-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}