{"product_id":"tsxdez08a5-schneider-electric-8-channel-ac-input-module","title":"TSXDEZ08A5 Schneider Electric 8-Channel AC Input Module","description":"\u003cp\u003eThe Schneider Electric \u003cstrong\u003eTSXDEZ08A5\u003c\/strong\u003e is an 8-channel AC discrete input module for the Modicon TSX Micro Automation Platform. It accepts 200-240 V AC field signals at 47-63 Hz through screw terminal blocks and converts them into discrete status signals for PLC processing. The module supports 2-wire proximity sensors and follows IEC 1131-2 Type 1 input requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Configuration and Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TSXDEZ08A5 provides eight AC input channels for detecting field device states. Its nominal input voltage range is 200-240 V AC, with an operating voltage range of 170-264 V. The 47-63 Hz frequency range supports both 50 Hz and 60 Hz AC supplies.\u003c\/p\u003e\n\u003cp\u003eThe input thresholds define the ON and OFF recognition conditions. A voltage of at least 120 V is recognized as logic state 1, while a voltage below 40 V is recognized as logic state 0. The specified state 0 current is no more than 5 mA, and the guaranteed state 1 current is at least 6 mA.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Response Time\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInput response time varies with signal transition direction and AC frequency. At 50 Hz, the transition from state 0 to state 1 takes 11-18 ms, while the transition from state 1 to state 0 takes 11-24 ms. At 60 Hz, the corresponding response times are 9-16 ms and 10-22 ms.\u003c\/p\u003e\n\u003cp\u003eThese response times should be considered when evaluating the module for applications involving rapid switching or short-duration input signals. The AC input response characteristics are different from those of high-speed DC input modules.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDEZ08A5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon TSX Micro Automation Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Voltage (Nominal)\u003c\/td\u003e\n\u003ctd\u003e200-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Input Voltage\u003c\/td\u003e\n\u003ctd\u003e170-264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current at 50 Hz\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current at 60 Hz\u003c\/td\u003e\n\u003ctd\u003e12 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage - State 1\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage - State 0\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 40 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnsure Current - State 0\u003c\/td\u003e\n\u003ctd\u003e= 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time, State 0 to State 1 at 50 Hz\u003c\/td\u003e\n\u003ctd\u003e11-18 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time, State 0 to State 1 at 60 Hz\u003c\/td\u003e\n\u003ctd\u003e9-16 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time, State 1 to State 0 at 50 Hz\u003c\/td\u003e\n\u003ctd\u003e11-24 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time, State 1 to State 0 at 60 Hz\u003c\/td\u003e\n\u003ctd\u003e10-22 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 1131-2 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Compatibility\u003c\/td\u003e\n\u003ctd\u003e2-wire proximity sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Category\u003c\/td\u003e\n\u003ctd\u003eCapacitive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC for 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging Type\u003c\/td\u003e\n\u003ctd\u003ePCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging Quantity\u003c\/td\u003e\n\u003ctd\u003e1 unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Height\u003c\/td\u003e\n\u003ctd\u003e5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Width\u003c\/td\u003e\n\u003ctd\u003e18.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Length\u003c\/td\u003e\n\u003ctd\u003e26.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging Weight\u003c\/td\u003e\n\u003ctd\u003e374 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many AC input channels does the TSXDEZ08A5 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The TSXDEZ08A5 provides eight discrete AC input channels connected through screw terminal blocks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What voltage is required for a valid ON signal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The input voltage must be at least 120 V for the module to guarantee recognition of state 1. A voltage below 40 V is recognized as state 0. The specified operating input range is 170-264 V AC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the TSXDEZ08A5 compatible with 2-wire proximity sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The supplied specifications identify compatibility with 2-wire proximity sensors. The sensor output voltage and current characteristics must also meet the module's input requirements.\u003c\/p\u003e","brand":"SCHNEIDER","offers":[{"title":"Default Title","offer_id":53357463044376,"sku":"TSXDEZ08A5","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/TSXDEZ08A4_Cocoai.jpg?v=1795145101","url":"https:\/\/www.innoplcsync.com\/products\/tsxdez08a5-schneider-electric-8-channel-ac-input-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}