{"product_id":"servo-axis-modules-allen-bradley-2094-am02","title":"Servo Axis Modules | Allen-Bradley 2094-AM02","description":"\u003cp\u003eThe \u003cstrong\u003e2094-AM02\u003c\/strong\u003e is an Allen-Bradley Kinetix 6000 axis module designed for motor control in multi-axis servo systems. It combines a DC link and inverter in a single module and supports motor feedback, auxiliary feedback, I\/O, and SERCOS fiber-optic communication. Its specified continuous output current is 10.6 A RMS, with a 4 kHz PWM frequency and a 500 Hz velocity-loop bandwidth.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2094-AM02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eKinetix 6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAxis Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Type\u003c\/td\u003e\n\u003ctd\u003eServo Inverter Axis Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current (RMS)\u003c\/td\u003e\n\u003ctd\u003e10.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current (0-Peak)\u003c\/td\u003e\n\u003ctd\u003e15.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e325 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWM Frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Loop Bandwidth\u003c\/td\u003e\n\u003ctd\u003e500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e0.98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Shunt Continuous Power\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Shunt Peak Power\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Shunt Resistor\u003c\/td\u003e\n\u003ctd\u003eNot Pre-installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShunt On\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.00 lbs (1.81 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e662453966151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eServo Drive Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 2094-AM02 integrates a DC link and inverter to provide the power conversion required for servo motor operation. Within a Kinetix 6000 multi-axis system, the axis module works with other system components to control an individual motor axis.\u003c\/p\u003e\n\u003cp\u003eThe 325 VDC nominal input voltage identifies the DC-link supply requirement rather than a direct AC mains input rating. System selection must account for the compatible power supply, DC bus configuration, motor requirements, and electrical ratings of the other installed modules.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCurrent and Motion Control Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module has a continuous current rating of 10.6 A RMS and a corresponding specified peak-format current value of 15.0 A (0-peak). These values are relevant when matching the axis module to the motor's electrical requirements and evaluating continuous operating conditions.\u003c\/p\u003e\n\u003cp\u003eIts 4 kHz PWM frequency defines the switching frequency used by the inverter power stage. The 500 Hz velocity-loop bandwidth describes the specified response capability of the velocity control loop; actual system performance also depends on motor characteristics, feedback configuration, and mechanical load.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeedback and Communication Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 2094-AM02 provides several front and top-side connectors for motor control, feedback, and system communication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMF (Motor Feedback):\u003c\/strong\u003e Connects the motor feedback interface used by the servo control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAF (Auxiliary Feedback):\u003c\/strong\u003e Provides an auxiliary feedback connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Connectors:\u003c\/strong\u003e Support the module's specified input\/output connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSERCOS Transmitter and Receiver:\u003c\/strong\u003e Provide fiber-optic communication interfaces for communication within the Kinetix 6000 motion control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-Segment Status Indicators:\u003c\/strong\u003e Display drive fault and status information for troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module also includes SERCOS communication-rate and optical-power adjustment switches. These settings should be coordinated with the communication configuration of the connected motion control system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMotor Power and Brake Connections\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe top-side connections include an MP (Motor Power) connector and a BC (Motor\/Resistive Brake) connector. The module also incorporates a motor cable shield clamp to accommodate the motor cable shielding arrangement.\u003c\/p\u003e\n\u003cp\u003eThe 2094-AM02 does not have a pre-installed internal shunt resistor. Therefore, an internal shunt resistor should not be assumed to be available for DC-bus regenerative energy management. Any required shunt configuration must be evaluated against the Kinetix 6000 system design.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied product information identifies the following compliance references:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korean Registration of Broadcasting and Communications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ec-Tick:\u003c\/strong\u003e Australian regulatory compliance marking for applicable radio communications requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Low Voltage Directive:\u003c\/strong\u003e Compliance reference for applicable electrical equipment safety requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm the applicable certification documentation and product revision when preparing formal regulatory or project compliance records.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the nominal input voltage of the 2094-AM02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified nominal input voltage is 325 VDC. This is the DC-link input rating, not a direct 200\/230 VAC mains voltage specification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 2094-AM02 include an internal shunt resistor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied product description states that the module does not have a pre-installed internal resistor. Internal shunt continuous and peak power values are listed as N\/A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication interface does the 2094-AM02 use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module provides SERCOS fiber-optic transmitter and receiver connections. It also includes switches for configuring the SERCOS communication rate and optical power.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53439836094744,"sku":"2094-AM02","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/2094-AM03-S_Cocoai_7cfdf2ce-56fb-416e-9b42-3e1234c5dc62.jpg?v=1795679379","url":"https:\/\/www.innoplcsync.com\/products\/servo-axis-modules-allen-bradley-2094-am02","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}