{"product_id":"schneider-electric-pc0984145-modicon-compact-984-plc-cpu","title":"Schneider Electric PC0984145 Modicon Compact 984 PLC CPU","description":"\u003cp\u003eThe Schneider Electric \u003cstrong\u003ePC0984145\u003c\/strong\u003e is a central processing unit for the Modicon Compact 984 automation architecture. It executes PLC control logic, mathematical operations, and register management for distributed I\/O systems. The specified configuration includes 4 kWords of user memory, two serial communication ports supporting Modbus RS232\/RS485, and support for up to 1024 discrete I\/O points.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProcessing and Memory\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe PC0984145 handles application logic and data processing within the Modicon Compact 984 platform. Its 4 kWords of user-accessible memory provide storage for controller logic and associated register data.\u003c\/p\u003e\n\u003cp\u003eAn onboard battery-backed memory circuit is specified for parameter retention during power loss. This function supports preservation of stored information when the controller supply is interrupted; battery type, service life, and replacement procedure are not provided.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe controller provides two serial communication ports supporting Modbus RS232 and RS485 communication. These interfaces allow the CPU to exchange data with compatible HMIs, engineering workstations, and other serial communication devices.\u003c\/p\u003e\n\u003cp\u003eRS232 and RS485 have different electrical interface characteristics and connection requirements. The exact port assignment, connector pinout, supported baud rates, and network configuration should be checked against the applicable hardware documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eI\/O Capacity and System Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe specified maximum capacity is 1024 discrete I\/O points. This defines the stated discrete signal capacity of the controller, rather than confirming the number of onboard physical I\/O terminals.\u003c\/p\u003e\n\u003cp\u003eThe CPU is intended for centralized logic processing in a distributed I\/O architecture. Actual system capacity and configuration depend on the supported I\/O assemblies and the hardware arrangement of the Modicon Compact 984 platform.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePC0984145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePLC CPU Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon Compact 984\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e4 kWords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 x Modbus serial ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Communication Standards\u003c\/td\u003e\n\u003ctd\u003eRS232 \/ RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e1024 discrete points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e1.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Backup\u003c\/td\u003e\n\u003ctd\u003eBattery-backed memory circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe specified power input is 5 VDC at 1.2 A. This corresponds to a nominal electrical input of 6 W based on the listed voltage and current.\u003c\/p\u003e\n\u003cp\u003eThe power connection and supply arrangement should be verified against the controller's installation documentation. The 5 VDC specification should not be interpreted as confirmation of direct connection to an external 5 V power supply without checking the intended system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum I\/O capacity of the PC0984145?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified maximum is 1024 discrete I\/O points. This is the stated controller capacity, not a confirmation of 1024 onboard physical terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many serial communication ports does the PC0984145 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied specifications identify two serial communication ports supporting Modbus RS232\/RS485. Confirm the individual port assignments and connector pinouts before connecting external equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the PC0984145 retain parameters when power is interrupted?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The supplied product description specifies an onboard battery-backed memory circuit for parameter retention during power loss. Battery maintenance and replacement requirements should be checked in the relevant hardware documentation.\u003c\/p\u003e","brand":"SCHNEIDER","offers":[{"title":"Default Title","offer_id":53318833537304,"sku":"PC0984145","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/PC09841452_Cocoai_1___2_11efe1dc-0ffe-42fa-94a5-65705ad5789a.jpg?v=1794884891","url":"https:\/\/www.innoplcsync.com\/products\/schneider-electric-pc0984145-modicon-compact-984-plc-cpu","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}