{"product_id":"schneider-electric-140noe21100c-modicon-quantum-ethernet-control-module","title":"Schneider Electric 140NOE21100C Modicon Quantum Ethernet Control Module","description":"\u003cp\u003eThe Schneider Electric \u003cstrong\u003e140NOE21100C\u003c\/strong\u003e is an Ethernet control module for the Modicon Quantum automation platform. It provides EtherNet\/IP and Modbus TCP communication through 10BASE-T\/100BASE-TX Ethernet interfaces, supporting full-duplex data exchange and up to 64 connections. The module also supports redundant hot-standby architectures, embedded network services, and an integrated four-port Ethernet switch.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEthernet Communication and Network Connectivity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 140NOE21100C supports two industrial communication protocols: EtherNet\/IP and Modbus TCP. Its Ethernet interface operates at 10\/100 Mbit\/s using RJ45 connections over twisted-pair cabling, with full-duplex communication for simultaneous data transmission and reception.\u003c\/p\u003e\n\u003cp\u003eThe module supports up to 64 communication connections. Its embedded four-port switch provides network connectivity for connected Ethernet devices, while the supported daisy-chain loop and redundant ring topologies offer different options for network layout.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRedundancy and Network Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supports a hot-standby redundant architecture and is specified for redundant ring and daisy-chain loop topologies. These capabilities allow it to operate within Ethernet network configurations designed for communication continuity.\u003c\/p\u003e\n\u003cp\u003eRedundancy implementation depends on the overall Quantum system architecture, network configuration, and compatible controller hardware. The presence of redundancy support should not be interpreted as automatic failover without the required system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140NOE21100C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd\u003e140CPU6xxxx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP, Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExchange Mode\u003c\/td\u003e\n\u003ctd\u003eFull duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Number of Connections\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003eRJ45, 10BASE-T\/100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Medium\u003c\/td\u003e\n\u003ctd\u003eTwisted pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded Switch\u003c\/td\u003e\n\u003ctd\u003e4-port Ethernet switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Topologies\u003c\/td\u003e\n\u003ctd\u003eRedundant ring, daisy-chain loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eHot-standby redundant architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb Server\u003c\/td\u003e\n\u003ctd\u003eEmbedded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDHCP\/BootP Server\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMTP Email Notification\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded Router\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIP Implicit Messaging\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIP Explicit Messaging\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSNMP Agent\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNTP Time Synchronization\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFDR Server\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality of Service (QoS)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type Manager (DTM)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Service\u003c\/td\u003e\n\u003ctd\u003eRapid Spanning Tree Protocol (RSTP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eVia rack power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Signalling\u003c\/td\u003e\n\u003ctd\u003e6 LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.345 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10-95% at 60 deg C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eUL 508, CSA C22.2 No 142, FM Class 1 Division 2, IEC 61000-4-16, EN 61131-1, EN 61131-2, EN 55011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eMerchant Navy, LR, C-Tick, GOST, Hazardous Location Class 1, Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which PLC platform is compatible with the Schneider Electric 140NOE21100C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 140NOE21100C belongs to the Modicon Quantum automation platform and lists compatibility with 140CPU6xxxx controllers. Verify the exact CPU model and system revision before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 140NOE21100C support redundant Ethernet communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The specifications identify hot-standby redundant architecture support and list redundant ring and daisy-chain loop topologies. Actual redundancy behavior depends on the system configuration and compatible hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication protocols are available on the 140NOE21100C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module supports EtherNet\/IP and Modbus TCP. It also provides CIP implicit and explicit messaging, along with network services such as SNMP, NTP, DHCP\/BootP, and SMTP.\u003c\/p\u003e","brand":"SCHNEIDER","offers":[{"title":"Default Title","offer_id":53424727130392,"sku":"140NOE21100C","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/140NOE21100C_Cocoai.jpg?v=1795487040","url":"https:\/\/www.innoplcsync.com\/products\/schneider-electric-140noe21100c-modicon-quantum-ethernet-control-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}