{"product_id":"schneider-electric-110cpu41102-plc-cpu-module","title":"Schneider Electric 110CPU41102 PLC CPU Module","description":"\u003cp\u003eThe \u003cstrong\u003e110CPU41102\u003c\/strong\u003e is a programmable logic controller (PLC) CPU module from Schneider Electric, featuring an integrated AC power supply and a combination of digital input and output points. It operates with an 8 MHz CPU and provides RS-232 communication and an RS-485 I\/O expansion port. The listed configuration includes 16 inputs, 8 TRIAC outputs, and 4 relay outputs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e110CPU41102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e110-CPU-411-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePLC CPU Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPU Speed\u003c\/td\u003e\n\u003ctd\u003e8 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTRIAC Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Expansion Port\u003c\/td\u003e\n\u003ctd\u003eRS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e32 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e1024 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Memory\u003c\/td\u003e\n\u003ctd\u003e512 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e4.10 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eIntegrated I\/O Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 110CPU41102 combines controller processing, power supply, and digital I\/O functions in one unit. Its 16 inputs provide digital signal acquisition, while the 8 TRIAC outputs and 4 relay outputs provide two different types of switching interfaces for external loads.\u003c\/p\u003e\n\u003cp\u003eTRIAC outputs use semiconductor switching and are generally associated with AC load control. Relay outputs use electromechanical contacts, allowing a different switching interface. Actual load voltage, current ratings, isolation specifications, and output protection requirements must be checked against the original hardware documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProcessing and Memory\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe controller operates at an 8 MHz CPU speed and has 32 KB of RAM. Its listed memory allocation includes 1024 words of program memory and 512 words of data memory.\u003c\/p\u003e\n\u003cp\u003eProgram memory stores the controller instructions, while data memory provides storage for application variables and operating values. These figures describe the listed memory configuration and should not be interpreted as additional or expandable memory capacity without manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication and I\/O Expansion\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides an RS-232 communication port for serial communication with compatible external equipment. An additional RS-485 port is identified for I\/O expansion, providing a separate interface for connecting supported expansion hardware.\u003c\/p\u003e\n\u003cp\u003eThe presence of these interfaces does not establish compatibility with every RS-232 or RS-485 device. Communication protocols, supported expansion modules, cabling requirements, and configuration limits should be verified before system replacement or integration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Availability and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 110CPU41102 is listed as \u003cstrong\u003ediscontinued by the manufacturer\u003c\/strong\u003e. This status is relevant when planning maintenance, spare-parts procurement, or replacement of existing PLC hardware.\u003c\/p\u003e\n\u003cp\u003eThe supplied seller information states that a Radwell 2-year warranty is included and that the manufacturer's factory warranty may not apply. Warranty coverage should therefore be distinguished from the original manufacturer's warranty.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the I\/O configuration of the 110CPU41102?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The listed configuration includes 16 digital inputs, 8 TRIAC outputs, and 4 relay outputs. These output types use different switching technologies and must be matched to the connected loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication interfaces are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module has an RS-232 communication port and an RS-485 I\/O expansion port. Supported protocols and compatible expansion hardware require confirmation from the applicable technical documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 110CPU41102 still manufactured?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied product listing identifies this model as discontinued by the manufacturer. Availability and warranty conditions depend on the supplier.\u003c\/p\u003e","brand":"SCHNEIDER","offers":[{"title":"Default Title","offer_id":53271022207256,"sku":"110CPU41102","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/110CPU51202_Cocoai_47983d69-91f7-4593-8365-0c8dae99c577.jpg?v=1794539789","url":"https:\/\/www.innoplcsync.com\/products\/schneider-electric-110cpu41102-plc-cpu-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}