{"product_id":"output-module-allen-bradley-1771-odd","title":"Output Module | Allen Bradley 1771-ODD","description":"\u003cp\u003eThe \u003cstrong\u003eAllen Bradley 1771-ODD\u003c\/strong\u003e is a 16-point Digital AC Output Module for the PLC 5 programmable controller platform. It provides isolated 120 V AC outputs for controlling external devices such as solenoids and transformers. The Series A module supports 1\/2-slot, 1-slot, and 2-slot addressing, with individual output status indicators and blown-fuse indication.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration and Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1771-ODD provides 16 isolated AC output points. Each output is controlled by its corresponding bit in the PLC data table, allowing the processor to determine the on\/off state of connected field devices.\u003c\/p\u003e\n\u003cp\u003eThe module operates within an AC voltage range of 85-138 V and has a maximum continuous current rating of 2 A per output. The total current across the module must not exceed 8 A, so individual output ratings cannot all be used simultaneously at their maximum values.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProtection and Status Indication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates surge suppression circuitry to limit high-voltage transients originating from the AC line. Optical coupling and filtering are also provided to reduce signal noise between the control logic and output circuitry.\u003c\/p\u003e\n\u003cp\u003eThere are 32 front-panel status indicators. Sixteen indicators on the left display the operating status of the individual outputs, while the 16 indicators on the right provide blown-fuse indications. These indicators help maintenance personnel identify output conditions during troubleshooting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePLC 5 Integration and Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1771-ODD is designed for installation in a compatible 1771 I\/O chassis containing a PLC processor. It supports 1\/2-slot, 1-slot, and 2-slot addressing configurations and uses 16 image bits per module.\u003c\/p\u003e\n\u003cp\u003eThe module uses chassis keying bands to help prevent incorrect insertion. The specified keying positions are pins 4-6 on the lower connector and pins 30-32 on the upper connector. A removable field wiring arm is identified in the supplied documentation, but its exact part number requires confirmation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1771-ODD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePLC 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital AC Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSeries A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eIsolated AC Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Category\u003c\/td\u003e\n\u003ctd\u003e120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e85-138 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Current per Output\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Module\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e420 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Format\u003c\/td\u003e\n\u003ctd\u003eBDC or Natural Binary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing\u003c\/td\u003e\n\u003ctd\u003e1\/2-slot, 1-slot, and 2-slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical AC Signal Delay (Off)\u003c\/td\u003e\n\u003ctd\u003e45 ms (+\/- 15 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical DC Signal Delay (Off)\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Signal Delay\u003c\/td\u003e\n\u003ctd\u003e10.6 ms (Off-to-On and On-to-Off, as stated in description)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e14.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Thermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e48.5 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Suppression\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eOptical Coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e32 (16 output status and 16 blown-fuse indicators)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e1771 I\/O Chassis, Rack Mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Arm\u003c\/td\u003e\n\u003ctd\u003e1771-WH \/ 1771-WN (requires confirmation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e612598141890\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.50 lbs (0.68 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Status\u003c\/td\u003e\n\u003ctd\u003eEarlier Model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary function of the Allen Bradley 1771-ODD?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 1771-ODD provides 16 isolated 120 V AC output points for controlling external devices. The PLC processor controls each output through its corresponding data table bit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can all 16 outputs operate at 2 A simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Although each output supports a maximum continuous current of 2 A, the total module current is limited to 8 A. The combined load must remain within this module-level rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked when replacing a 1771-ODD module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify the PLC 5 chassis configuration, addressing arrangement, connector keying positions, and field wiring arm part number. The supplied information identifies two different wiring arm numbers, 1771-WH and 1771-WN, which should be confirmed before ordering a replacement.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53357253755160,"sku":"1771-ODD","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/1771-WS_2__Cocoai_65e3700b-d070-46c1-8a72-8c65b27f96f1.jpg?v=1795141011","url":"https:\/\/www.innoplcsync.com\/products\/output-module-allen-bradley-1771-odd","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}