{"product_id":"operator-terminal-allen-bradley-2711-t10g20l1-panelview-1000-standard","title":"Operator Terminal | Allen Bradley 2711-T10G20L1 PanelView 1000 Standard","description":"\u003cp\u003eThe \u003cstrong\u003eAllen Bradley 2711-T10G20L1\u003c\/strong\u003e serves as the primary \u003cstrong\u003e2711-T10G20L1\u003c\/strong\u003e Operator Terminal utilized to execute process command input and screen display visualization across Ethernet network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T10G20L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in technical documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.00 lbs (2.72 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PanelView 1000 physical chassis profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C (32 to 131 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e39 W (132 BTU\/HR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 32 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eActive Matrix TFT Grayscale with CCF Backlight (4 shades of gray)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10.1 in. (211 x 158 mm active area)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Life\u003c\/td\u003e\n\u003ctd\u003e100,000 hr LED backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Input\u003c\/td\u003e\n\u003ctd\u003eAnalog resistive, 384 touch cells (24 columns x 16 rows)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-232 (Printer port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 12, 13, or 4X (indoor use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Network Connectivity and Firmware Execution\u003c\/h3\u003e\n\u003cp\u003eThe terminal leverages high-speed EtherNet\/IP deterministic networks to facilitate continuous data packet exchange with host controllers and automated process nodes. Flash memory housing integrated execution firmware ensures deterministic communication processing, real-time alarm handling, and reliable program execution. Supplementary RS-232 connections allow direct serial output transmission to external printing units for event logging without backplane processing overhead.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input power source configuration is required to operate the 2711-T10G20L1 terminal?\u003c\/p\u003e\n\u003cp\u003eA: The terminal requires a DC supply voltage range of 18 to 32 VDC, with a nominal rating of 24 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What physical touch interface structure does the 10.1-inch display utilize?\u003c\/p\u003e\n\u003cp\u003eA: The analog resistive touch screen features 384 individual touch cells configured in a matrix of 24 columns by 16 rows, each measuring 26 x 30 pixels.\u003c\/p\u003e\n\u003cp\u003eQ: What primary interface protocols handle control network data transfer and printing functions?\u003c\/p\u003e\n\u003cp\u003eA: Control data and process tag values are transferred over an industrial Ethernet communication port, while localized event documentation is sent through an embedded RS-232 printer port.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePanel Mounting Integrity: Install the terminal into a cut panel space and secure all mounting clamps to ensure proper sealing against NEMA Type 12, 13, or 4X environmental standards.\u003c\/li\u003e\n\u003cli\u003eDC Power Connection: Wire 24 VDC power lines directly to the input terminal block, observing correct polarity and establishing a dedicated low-impedance earth ground to protect sensitive electronics.\u003c\/li\u003e\n\u003cli\u003eSignal Conduits \u0026amp; Interference: Route Ethernet and RS-232 communication lines through grounded shielding pathways separated from high-voltage AC lines to prevent signal corruption.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53000930328856,"sku":"2711-T10G20L1","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/2711-T6C9L12_Cocoai_97d62faa-ca92-4e6a-98c4-c82c64a21924.jpg?v=1792725871","url":"https:\/\/www.innoplcsync.com\/products\/operator-terminal-allen-bradley-2711-t10g20l1-panelview-1000-standard","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}