{"product_id":"latching-input-module-allen-bradley-1771-ds","title":"Latching Input Module | Allen-Bradley 1771-DS","description":"\u003cp\u003eThe \u003cstrong\u003e1771-DS\u003c\/strong\u003e is an 8-point latching digital input module from Allen-Bradley, designed for the 1771 I\/O chassis used in PLC-5 control systems. It detects and retains short-duration DC input pulses, allowing the controller to register signals that may occur between normal I\/O scans. The module supports selectable pulse capture times and independent or paired input operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Detection and Latching Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1771-DS detects pulses from optical sensors with isolated pulse and gate outputs. When a valid pulse is detected, the module sets the corresponding bit in the input image table on the next I\/O scan. This latching function allows short events to be registered without requiring the controller to observe the input while the pulse is present.\u003c\/p\u003e\n\u003cp\u003eThe module supports pulse capture times of \u003cstrong\u003e0.1, 0.5, 1.0, 2.5, and 5.0 ms\u003c\/strong\u003e. Each input can be configured for independent operation or paired operation, depending on the signal arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIndependent and Paired Input Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIn independent mode, each input detects pulses separately, making it suitable for single-pulse signals. In paired mode, one input provides a gate signal while the other receives the pulse signal. The module combines these signals to determine whether a pulse should be latched, supporting selected pulse detection in multi-pulse applications.\u003c\/p\u003e\n\u003cp\u003eUp to four input pairs can be configured per module. The optical sensors must provide isolated pulse and gate outputs, and their off-state leakage current must not exceed 1 mA at 4 V DC.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1771-DS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLatching Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic 1 Input Voltage\u003c\/td\u003e\n\u003ctd\u003e10-27 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic 0 Input Voltage\u003c\/td\u003e\n\u003ctd\u003e0-4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Capture Time\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.5, 1.0, 2.5, or 5.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Current\u003c\/td\u003e\n\u003ctd\u003e20 mA at 27 VDC (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-State Current\u003c\/td\u003e\n\u003ctd\u003e1 mA at 4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Voltage Protection\u003c\/td\u003e\n\u003ctd\u003e240 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpto-Electrical Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e375 mA (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Location\u003c\/td\u003e\n\u003ctd\u003e1771 I\/O chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.05 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued 03\/30\/2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of input signals does the 1771-DS detect?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It detects short-duration DC pulses from optical sensors with isolated pulse and gate outputs. The module supports pulse capture times from 0.1 to 5.0 ms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between independent and paired input operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Independent mode processes individual pulse inputs separately. Paired mode uses a gate input together with a pulse input, allowing the module to latch selected pulses in applications involving multiple pulse signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1771-DS retain short input pulses between PLC scans?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module latches a detected pulse and sets the corresponding input image table bit on the next I\/O scan. This allows the PLC to register pulses that are shorter than its normal scan interval.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSEO Field\u003c\/th\u003e\n\u003cth\u003eContent\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEO Title\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley 1771-DS Latching Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeta Description\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley 1771-DS 8-point latching DC input module with selectable pulse capture times from 0.1 to 5.0 ms.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLatching Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTags\u003c\/td\u003e\n\u003ctd\u003e1771 I\/O, Latching Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003e\u003cstrong\u003eAllen-Bradley 1771-IDC Isolated AC\/DC Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e1771-IDC\u003c\/strong\u003e is a six-channel isolated AC\/DC digital input module for Allen-Bradley PLC-5 systems. Designed for the 1771 I\/O platform, it accepts 120 V-class AC or DC discrete input signals from field devices. Its input filtering helps limit the effects of contact bounce and electrical noise, while isolated input channels provide separation between field signals and the controller interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Configuration and Signal Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides six isolated digital input channels for monitoring ON\/OFF field devices. Its nominal 120 V AC\/DC input category supports both alternating-current and direct-current signals within the specified operating voltage range.\u003c\/p\u003e\n\u003cp\u003eInput filtering introduces a defined response delay when the signal changes state. This filtering helps prevent brief disturbances from contact bounce or electrical noise from being interpreted as valid input transitions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Delay and Chassis Power\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AC and DC input circuits have different response characteristics. AC signals have a nominal delay of 24 ms with a +\/-10 ms tolerance for both ON and OFF transitions. DC signals have a 10 ms delay (+\/-4 ms) when turning ON and a 20 ms delay (+\/-9 ms) when turning OFF.\u003c\/p\u003e\n\u003cp\u003eThe module draws its operating power from the 1771 I\/O chassis backplane. Its 74 mA backplane current requirement should be included when calculating the total current demand of the installed I\/O modules.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53424680894744,"sku":"1771-DS","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/1771-IM_Cocoai_be7b1303-5820-4f6f-9fc0-0db4947e94e1.jpg?v=1795483947","url":"https:\/\/www.innoplcsync.com\/products\/latching-input-module-allen-bradley-1771-ds","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}