{"product_id":"honeywell-tp-dikbta-100-51196694-300-industrial-keyboard","title":"Honeywell TP-DIKBTA-100 51196694-300 Industrial Keyboard","description":"\u003cdiv class=\"qk-md-paragraph qk-md-has-multi-modal\"\u003e\n\u003cp\u003eConfigured for operator input and cursor control in Honeywell HMI, MMI, and OIT platforms, the \u003cstrong\u003eHoneywell TP-DIKBTA-100\u003c\/strong\u003e (\u003cstrong\u003e51196694-300\u003c\/strong\u003e Industrial Keyboard with Trackball) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (TP-DIKBTA-100):\u003c\/strong\u003e Designates the complete industrial keypad hardware assembly with integrated tracking ball.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number (51196694-300):\u003c\/strong\u003e Defines the exact internal PCB logic component build, hardware revision code, and standardized Honeywell HMI interface configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTP-DIKBTA-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51196694-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e15 lbs (6.8 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard desk-mounted or panel-integrated industrial footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard loop\/bus powered via Honeywell HMI connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIndustrial Keyboard with Trackball\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eHMI \/ MMI \/ OIT Sub-assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Format\u003c\/td\u003e\n\u003ctd\u003eDesk-mounted or panel-integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eSealed construction resistant to dust and mechanical wear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Interface \u0026amp; Channel-to-Channel Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eIn process automation and DCS environments, operator input peripherals interface directly with operator station nodes maintaining deterministic signal integrity. The unit utilizes channel-to-channel isolation and hardened signal processing across the standard Honeywell HMI connection bus to prevent ground loops and common-mode electrical noise injection into connected operator interface terminals. High-durability trackball optics and contact switches provide reliable feedback response and mechanical wear resistance across extended control room cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the interface cable grounding requirements when panel-mounting the TP-DIKBTA-100?\u003c\/p\u003e\n\u003cp\u003eA: The unit must be bonded to the central panel earth ground using a dedicated ground lug or braid. Shielded communication cables connected to the Honeywell HMI interface must be grounded at one end only to eliminate ground loop current injection across signal lines.\u003c\/p\u003e\n\u003cp\u003eQ: Can the integrated trackball assembly be cleaned or serviced in field environments?\u003c\/p\u003e\n\u003cp\u003eA: Field maintenance should be performed with power isolated from the HMI node. The mechanical housing provides dust resistance; external surfaces and trackball aperture should be cleared using dry low-pressure instrument air or isopropyl alcohol wipes without disassembling internal circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Ensure panel cutouts match specified dimensions for flush integration. For desk-mounted layouts, ensure the unit rests on a stable, vibration-dampened horizontal surface. Maintain at least 50 mm clearance behind rear panel connectors for cable bend radius.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Grounding:\u003c\/strong\u003e Connect all Honeywell interface cables securely using integrated locking screws. Verify protective earth (PE) connection continuity to the industrial enclosure ground bus prior to energizing the workstation node.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protections:\u003c\/strong\u003e Do not subject the keypad or trackball assembly to high-pressure washdowns or corrosive solvent exposure beyond standard industrial atmospheric ratings. Ensure operating ambient temperatures stay within designated operational limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eal alarm monitoring and manual control functions across Experion PKS, Safety Manager, FSC, and legacy TDC 3000 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTP-OPADP1-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51305776-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Automation Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNominal industrial panel weight (data not provided)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard panel-mount footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard baseline (0 to 60 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via standard DCS instrument bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eOperator Advisor Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Integration\u003c\/td\u003e\n\u003ctd\u003eExperion PKS, Safety Manager, FSC, TDC 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Format\u003c\/td\u003e\n\u003ctd\u003eRugged panel-mounted interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Connectivity \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eWithin process control environments, this operator panel integrates directly with DCS controllers while maintaining strict deterministic signal parameters. The internal communication hardware employs optical channel-to-channel isolation to block common-mode voltage transients and ground loops from disrupting the main Experion PKS or TDC 3000 data highways. This galvanic separation ensures that local interface operations do not compromise the integrity of critical analog and digital signal processing executing on the master controller.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane communication limits when integrating the TP-OPADP1-200 with legacy TDC 3000 networks?\u003c\/p\u003e\n\u003cp\u003eA: Integration requires configuring the panel node within the standard network architecture limits, ensuring the polling cycles do not exceed the predefined bandwidth allocation of the TDC 3000 Local Control Network (LCN).\u003c\/p\u003e\n\u003cp\u003eQ: Does the unit support hot-swapping during active process operations?\u003c\/p\u003e\n\u003cp\u003eA: Panel components must be powered down prior to physical removal. Disconnecting the active communication bus under power without software detaching can cause transient faults on the control network.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Integration:\u003c\/strong\u003e Ensure the panel cutout meets the required dimensional tolerances for flush mounting. Secure all perimeter mounting clips evenly to prevent ingress of dust and moisture in NEMA\/IP-rated control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Grounding:\u003c\/strong\u003e Bond the chassis earth terminal to the main control cabinet ground bus using a low-impedance braided copper strap. Ensure that shielding for the communication cables is terminated according to Honeywell guidelines to mitigate electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Routing:\u003c\/strong\u003e Maintain strict spatial separation between low-voltage DCS communication lines connecting to the TP-OPADP1-200 and high-voltage AC power wiring within the same cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52597048770840,"sku":"TP-DIKBTA-100 51196694-300","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/TDCS3000LCN_2_e391431f-2302-4efb-b0e8-7760d7e9717a.png?v=1788250382","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-tp-dikbta-100-51196694-300-industrial-keyboard","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}