{"product_id":"honeywell-tdcs3000lcn-programmable-controller-module","title":"Honeywell TDCS3000LCN Programmable Controller Module","description":"\u003cdiv class=\"qk-md-paragraph qk-md-has-multi-modal\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TDCS3000LCN\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTDCS3000LCN\u003c\/strong\u003e Programmable Controller Module, operates as a dedicated hardware component for advanced control execution within Honeywell Total Digital Control System (TDCS) 3000 networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTDCS3000LCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Automation Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e9.5 x 10 x 2.5 inches (241 x 254 x 64 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 60 deg C (-40 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via Honeywell TDCS bus interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA or 0-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eProgrammable Controller Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Interface \u0026amp; 4-20 mA HART Loop Protocol Integration\u003c\/h3\u003e\n\u003cp\u003eThe controller processes 4-20 mA and 0-10 V analog outputs with precision tolerances (+\/-0.2% accuracy). To guarantee signal integrity across Honeywell DCS architectures, the module incorporates channel-to-channel isolation to prevent ground loop noise from corrupting field instrumentation loops. The onboard analog output stages interface directly with 4-20 mA HART loop protocol networks, permitting field device data integration while maintaining deterministic loop control updates.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the TDCS3000LCN support hot-swapping while the TDCS 3000 backplane is energized?\u003c\/p\u003e\n\u003cp\u003eA: Module insertion or removal must be performed with local power disconnected to avoid electrical arc damage to the connector pins and prevent bus communication interruption on active adjacent modules.\u003c\/p\u003e\n\u003cp\u003eQ: How is signal degradation prevented on long 4-20 mA analog output wiring runs?\u003c\/p\u003e\n\u003cp\u003eA: Ensure high-quality shielded twisted-pair cabling is installed, with the cable shield grounded at a single point on the DCS panel earth bus to eliminate common-mode ground loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Installation:\u003c\/strong\u003e Mount the module securely in designated control panels according to standard clearance rules. Ensure a minimum of 50 mm clearance around the housing to facilitate natural thermal convection and maintain operating temperatures within the -40 to 60 deg C rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Wiring:\u003c\/strong\u003e Wire analog outputs (4-20 mA \/ 0-10 V) using shielded, twisted-pair cables. Terminate cable shielding strictly at the control cabinet single-point ground bar to prevent ground loop current injection into field control circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Limits:\u003c\/strong\u003e Verify that the installation enclosure prevents condensation, maintaining relative humidity strictly within the 5 to 95% non-condensing range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52597048836376,"sku":"TDCS3000LCN","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/TDCS3000LCN.png?v=1788250367","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-tdcs3000lcn-programmable-controller-module","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}