{"product_id":"honeywell-rs232-cable-5m-serial-communication-cable","title":"Honeywell RS232 CABLE 5M Serial Communication Cable","description":"\u003cdiv class=\"qk-md-paragraph qk-md-has-multi-modal\"\u003e\n\u003cp\u003eConfigured for serial data exchange in Honeywell automation platforms, the \u003cstrong\u003eHoneywell RS232 CABLE 5M\u003c\/strong\u003e (\u003cstrong\u003eRS232 CABLE 5M\u003c\/strong\u003e Serial Communication Cable) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRS232 CABLE 5M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Automation Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNominal cable weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5 meters (16.4 feet) length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C (-4 to +140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive hardware component (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Material\u003c\/td\u003e\n\u003ctd\u003eHigh-quality PVC insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eRS232 connectors (DB9 male\/female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell devices with RS232 interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Interface \u0026amp; Channel-to-Channel Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eIn process control and DCS network architectures, serial communication links transport configuration data, diagnostics, and protocol frames between host controllers and peripheral devices. This 5-meter cable assembly utilizes high-quality PVC insulation and internal drain shielding to reduce common-mode electrical noise and cross-talk across serial transmit\/receive channels. When connected to isolated RS232 ports on Honeywell interface cards, the assembly maintains system signal integrity and galvanic isolation between connected control nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the RS232 CABLE 5M be field-cut or spliced to alter its operational length?\u003c\/p\u003e\n\u003cp\u003eA: Cutting or field-splicing the assembly compromises the overall shield continuity and signal attenuation characteristics, which can lead to data bit errors across serial transmission lines.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum operating temperature limit for permanent cable routing? A: The cable sheath and internal conductor insulation are rated for continuous operational exposure from -20 to +60 deg C (-4 to +140 deg F).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing \u0026amp; Bending:\u003c\/strong\u003e Maintain a minimum bend radius equal to ten times the outer cable diameter during installation. Avoid sharp bends near DB9 connector backshells to prevent internal conductor fatigue.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Mitigation:\u003c\/strong\u003e Route the serial cable through dedicated low-voltage instrument raceways. Maintain physical separation from high-voltage AC power lines to prevent electromagnetic interference (EMI) on serial data frames.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Securing:\u003c\/strong\u003e Fully seat DB9 connectors into mating equipment ports and tighten the captive retention thumbscrews to secure the physical connection and maintain shield grounding continuity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52597052473624,"sku":"RS232 CABLE 5M","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/RS232-CABLE-5M_1200x1200_4e86a35b-0921-4619-98ae-1b005f99d27e.jpg?v=1788250121","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-rs232-cable-5m-serial-communication-cable","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}