{"product_id":"honeywell-mu-taih02-51304453-100-analog-input-terminal-assembly","title":"Honeywell MU-TAIH02 51304453-100 Analog Input Terminal Assembly","description":"\u003cdiv class=\"qk-md-paragraph qk-md-has-multi-modal\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MU-TAIH02 51304453-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMU-TAIH02\u003c\/strong\u003e High-Level Analog Input Terminal Assembly (FTA), operates as a dedicated hardware component for high-level analog signal conditioning and field transmitter termination within Honeywell DCS platforms. It provides direct physical wiring interface points between field instrumentation and central processing controllers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-TAIH02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51304453-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input Terminal Assembly (FTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Signal Types\u003c\/td\u003e\n\u003ctd\u003eHigh-level analog signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell DCS platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel \/ DIN rail installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Options\u003c\/td\u003e\n\u003ctd\u003eScrew and compression terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e36.5 cm x 36.5 cm x 2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive field termination assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eDesigned to route field signals into high-level analog input cards, the MU-TAIH02 FTA interface integrates passive signal conditioning pathways compatible with standard 4-20 mA HART loop protocol instruments. The physical trace routing on the board provides channel-to-channel isolation, preventing common-mode noise propagation and ground potential shifts from affecting controller input conversion circuitry. This layout ensures high-precision analog signal fidelity between transmitter wiring terminals and control system I\/O buses.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What termination wire connection choices are supported on the MU-TAIH02 terminal assembly?\u003c\/p\u003e\n\u003cp\u003eA: The unit features field-configurable terminal blocks supporting both screw and compression wire termination methods.\u003c\/p\u003e\n\u003cp\u003eQ: How is the MU-TAIH02 physically mounted inside a control cabinet?\u003c\/p\u003e\n\u003cp\u003eA: The board supports standard panel mounting or DIN rail installation configurations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Procedure:\u003c\/strong\u003e Fasten the 36.5 cm x 36.5 cm frame securely to the cabinet backplane or DIN rail system. Verify structural stability before landing field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Connect field instrument cable shields directly to the designated cabinet grounding busbar to prevent noise coupling across the high-level input channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Practice:\u003c\/strong\u003e Strip field wiring insulation to 7 mm prior to landing conductors into screw or compression terminals. Maintain physical separation between high-level analog signal lines and AC power cables within cabinet wire trunks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Ensure ambient enclosure temperatures remain within target control room specifications to prevent thermal stress on conformal coatings.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52602593181976,"sku":"MU-TAIH02 51304453-100","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/MU-TAIH02_1_df5c3e96-5ff8-48c5-8014-f25868a06d15.png?v=1788334677","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-mu-taih02-51304453-100-analog-input-terminal-assembly","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}