{"product_id":"honeywell-mp904a5047-pneumatic-motor","title":"Honeywell MP904A5047 Pneumatic Motor","description":"\u003cdiv class=\"qk-md-paragraph qk-md-has-multi-modal\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MP904A5047\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMP904A5047\u003c\/strong\u003e Pneumatic Motor, operates as a dedicated hardware component for mechanical valve and damper actuation within process control systems. It directly converts applied compressed air pressure into a linear stroke displacement of 90 mm.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMP904A5047\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eMotor \/ Pneumatic Actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Pressure\u003c\/td\u003e\n\u003ctd\u003e140 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Safe Air Pressure\u003c\/td\u003e\n\u003ctd\u003e210 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Stroke\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Connection\u003c\/td\u003e\n\u003ctd\u003eBarb fitting for 6 mm (1\/4 in) polyethylene tubing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e12.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Actuator Housing Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eCompressed Air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eDesigned for pneumatic actuation loops, the MP904A5047 interfaces with electropneumatic positioners converting 4-20 mA HART loop protocol control signals into proportional air pressure. The physical mechanical assembly provides complete galvanic and electrical channel-to-channel isolation from process instrumentation circuits. This ensures high-accuracy pneumatic position control up to the 140 kPa maximum operating pressure limit without introducing electrical ground loops into associated controller field buses.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What air supply tubing diameter is supported by the MP904A5047 pneumatic connection?\u003c\/p\u003e\n\u003cp\u003eA: The motor features an integrated barb fitting designed for 6 mm (1\/4 in) polyethylene tubing.\u003c\/p\u003e\n\u003cp\u003eQ: What are the maximum operating and safe burst pressure ratings for this actuator?\u003c\/p\u003e\n\u003cp\u003eA: The maximum operating pressure is 140 kPa, and the maximum safe air pressure limit is 210 kPa.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Line Connection:\u003c\/strong\u003e Push clean, dry 6 mm (1\/4 in) polyethylene tubing firmly onto the integrated barb fitting until seated completely. Secure with a tubing clamp if necessary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Regulation:\u003c\/strong\u003e Install a upstream air filter regulator set to not exceed the maximum operating pressure of 140 kPa. Never exceed the absolute safe limit of 210 kPa.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Linkage Alignment:\u003c\/strong\u003e Ensure the actuator push rod is aligned precisely with the driven damper or valve linkage to prevent side-loading during the full 90 mm stroke.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeak Testing:\u003c\/strong\u003e Apply pneumatic pressure and inspect all supply line fittings with soapy water to verify zero bubble formation prior to system commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52602595377432,"sku":"MP904A5047","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0892\/3483\/3688\/files\/3.png?v=1788334646","url":"https:\/\/www.innoplcsync.com\/products\/honeywell-mp904a5047-pneumatic-motor","provider":"InnoPLC Sync Co., Ltd.","version":"1.0","type":"link"}